OSHA SearchOSHA records by employer

Structural Roof Systems, Inc.: OSHA inspections and violations

Fort Lauderdale, Florida · Roofing Contractors · NAICS 238160

3inspections
5citation items
$4,799current penalties
Feb 23, 2016last inspection

Since 2004, OSHA inspectors have visited Structural Roof Systems, Inc. in Florida 3 times.

The most recent inspection opened on Feb 23, 2016 on a referral, in Fort Lauderdale.

In all, OSHA issued 5 citation items: 4 serious and 1 other-than-serious.

The proposed penalties came to $6,725; today they stand at $4,799, 29% less.

The rule cited most here is 1910.213 (woodworking machinery), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Structural Roof Systems, Inc. averages $3,430 across 1 cited inspection.

Structural Roof Systems, Inc. also files yearly injury logs with OSHA, summarized below.

It reported 1 severe injury to OSHA since 2015.

Structural Roof Systems, Inc.: OSHA citation items per year, 2004 to 2016
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

318employers cited

66 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Structural Roof Systems, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341266500 OPENED FEB 23, 2016Closed

Referral · Partial · Safety · 45 employees at the site · Closed Aug 29, 2016

2703 Nw 55 Court, Fort Lauderdale, FL 33309 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$4,900$3,430Jul 27, 2016Final
Citation 1, item 1b
29 CFR 1910.213(c)(2) · Woodworking machinery
Serious$0$0Jul 27, 2016Final
Citation 1, item 1c
29 CFR 1910.213(c)(3) · Woodworking machinery
Serious$0$0Jul 27, 2016Final

Inspection 311087928 OPENED DEC 28, 2007Closed

Planned · Partial · Safety · 3 employees at the site · Closed Jan 9, 2008

Se Corner Of Us-1 And 17th Street, Fort Lauderdale, FL 33316 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$700$525Jan 2, 2008Closed

Inspection 307302661 OPENED OCT 14, 2004Closed

Unprogrammed related · Complete · Safety · 10 employees at the site · Closed Apr 1, 2005

901 South Federal Highway, Hallandale, FL 33009 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Other-than-serious$1,125$844Mar 1, 2005Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2023, the Fort Lauderdale site logged 2 recordable injuries or illnesses among about 31 workers: 6.2 per 100 full-time workers, against a median of 2.8 for its industry. Those cases cost 9 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Structural Roof Systems, Inc.
Fort Lauderdale · 2023
31 216.22.8

Included with any plan: 3 more yearly logs from these sites, back to 2019, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Feb 19, 2016, Fort Lauderdale: Hospitalization, amputation · amputations · finger(s), fingernail(s), unspecified

An employee was cutting pieces of wood using a table saw. A piece of wood slipped and his right hand contacted the blade, cutting three fingers.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.213(c)(1)

(c) Hand-fed ripsaws. (1) Each circular hand-fed ripsaw shall be guarded by a hood which shall completely enclose that portion of the saw above the table and that portion of the saw above the material being cut. The hood and mounting shall be arranged so that the hood will automatically adjust itself to the thickness of and remain in contact with the material being cut but it shall not offer any considerable resistance to insertion of material to saw or to passage of the material being sawed. The hood shall be made of adequate strength to resist blows and strains incidental to reasonable operation, adjusting, and handling, and shall be so designed as to protect the operator from flying splinters and broken saw teeth. It shall be made of material that is soft enough so that it will be unlikely to cause tooth breakage. The hood shall be so mounted as to insure that its operation will be po

29 CFR 1910.213(c)(2)

(2) Each hand-fed circular ripsaw shall be furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator. The spreader shall be made of hard tempered steel, or its equivalent, and shall be thinner than the saw kerf. It shall be of sufficient width to provide adequate stiffness or rigidity to resist any reasonable side thrust or blow tending to bend or throw it out of position. The spreader shall be attached so that it will remain in true alignment with the saw even when either the saw or table is tilted. The provision of a spreader in connection with grooving, dadoing, or rabbeting is not required. On the completion of such operations, the spreader shall be immediately replaced.

29 CFR 1910.213(c)(3)

(3) Each hand-fed circular ripsaw shall be provided with nonkickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator. They shall be designed to provide adequate holding power for all the thicknesses of materials being cut.

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.501 · Fall protection in construction

Other roofing contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.