Stuart Dean Co Inc: OSHA inspections and violations
Los Angeles, California · Electroplating, Plating, Polishing, Anodizing, and Coloring · NAICS 332813
9inspections
24citation items
$17,580current penalties
Mar 30, 2018last inspection
OSHA has inspected Stuart Dean Co Inc 9 times in California since 1988.
The latest one began on Mar 30, 2018 after an accident, in Cupertino.
Those inspections ended with 24 citation items: 6 serious and 18 other-than-serious.
Penalties were first proposed at $38,980 and now stand at $17,580, 55% lower after settlements or reviews.
Job-site wiring comes up most often in these citations: 3 items under 1926.405.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Stuart Dean Co Inc averages $12,200 (1 cited inspection).
Stuart Dean Co Inc also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
California · latest 90 days of OSHA records
1,120employers cited
Get notified the morning OSHA posts each new citation in California: the employer, the site address, the rules broken and the penalty.
Incident on Mar 27, 2018: Employee falls from ladder and injures head and back
At 10:45 a.m. on March 27, 2018, Employee #1, employed by an architectural restoration company, was painting a building's exterior wall. As he worked from a Louisville 10-foot A-frame ladder, he fell, a fall height of approximately 8 feet. Emergency services were called, and Employee #1 was transported to the hospital. He was admitted and treated for injuries to his head and back. head and back.
Citation and rule
Type
Proposed
Current
Issued
Status
Citation 1, item 2
29 CFR 1509(B)
Other-than-serious
$600
$450
Jun 26, 2018
Final
Citation 1, item 3
29 CFR 1512(I)
Other-than-serious
$600
$450
Jun 26, 2018
Final
Citation 1, item 4
29 CFR 3395(H)(1)
Other-than-serious
$600
$450
Jun 26, 2018
Final
Citation 1, item 5
29 CFR 3395(I)
Other-than-serious
$600
$450
Jun 26, 2018
Final
Citation 2, item 1
29 CFR 1512(A)
Serious
$7,200
$5,400
Jun 26, 2018
Final
Citation 3, item 1
29 CFR 3276(F)
Other-than-serious
$18,000
$5,000
Jun 26, 2018
Final
Inspection 314865106 OPENED MAY 15, 2013Closed
Unprogrammed related · Partial · Safety · 60 employees at the site · Closed Apr 25, 2017
Incident on Jun 5, 2003: Employee falls from swing stage scaffold
On June 5, 2003, Employee #1 and a coworker were cleaning the exterior steel of a building. This is accomplished through the use of a site-unique suspended scaf fold, designed and engineered by Skymaster Corporation. Employee #1 and a cowork er were in the process of moving the scaffold. The scaffold is suspended by an a rm that rides on a tracked trolley. The trolley rides on a pair of rails that ar e 10 in. in diameter. The track goes around the periphery of the roof which is h igh on the north and south faces, and lower on the east and west faces. The trol ley was being traversed from the southeast face around a corner where a 14 degre e slope began decent to the middle of the east face, then back uphill to the nor theast face. Employee #1 was riding in the scaffold and the coworker was operati ng the electric motor controls from the roof, along side the scaffold. As it beg an to descend the trolley began to slide on the rails, it gained speed until it reached the bottom of the slope then continued to slide uphill 35 ft, where the scaffold began to swing to the side. At this time Employee #1 was ejected from t he scaffold, but was held to the scaffold by his fall protection harness. As he and the scaffold swung sideways the scaffold contacted some of the steel walls w hose edges were sharp. This sliding along the walls cut the fall protection lany ard, causing the Employee #1 to fall approximately 2 ft to a structural glass ce iling. He received minor bruises and a small cut on his forehead. He was not hos pitalized.
Citation and rule
Type
Proposed
Current
Issued
Status
Citation 1, item 1
29 CFR 3294 I
Other-than-serious
$185
$185
Dec 3, 2003
Closed
Citation 1, item 2
29 CFR 3295 C01 F
Other-than-serious
$185
$185
Dec 3, 2003
Closed
Inspection 120301395 OPENED APR 21, 1999Closed
Unprogrammed related · Partial · Health · 13 employees at the site · Closed Apr 21, 1999
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Los Angeles site logged 0 recordable injuries or illnesses among about 35 workers: 0.0 per 100 full-time workers, against a median of 0.1 for its industry.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Stuart Dean - Los Angeles
Los Angeles · 2025
35
0
0
0.0
0.1
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
(a) The employer is responsible for requiring the wearing of appropriate personal protective equipment in all operations where there is an exposure to hazardous conditions or where this part indicates the need for using such equipment to reduce the hazards to the employees.
(b) Branch circuits—(1) Ground-fault protection—(i) General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.
29 CFR 1926.404(f)(6)
(6) Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.
Alert subscribers get notified of each newly cited employer in California the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.