OSHA SearchOSHA records by employer

Styline Diesel Service Center Inc: OSHA inspections and violations

Huntingburg, Indiana · General Automotive Repair · NAICS 811111

3inspections
4citation items
$5,000current penalties
Dec 6, 2017last inspection

OSHA has inspected Styline Diesel Service Center Inc 3 times in Indiana since 1995.

The latest one began on Dec 6, 2017 after a fatality or catastrophe, in Huntingburg.

Those inspections ended with 4 citation items: 1 serious and 3 other-than-serious.

Penalties were first proposed at $7,000 and now stand at $5,000, 29% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for repair and personal services employers since 2015 is $1,200, and Styline Diesel Service Center Inc averages $5,000 (1 cited inspection).

1 inspection on this page followed a fatal incident.

Styline Diesel Service Center Inc: OSHA citation items per year, 1995 to 2017
Citation items per year, by inspection date.

Indiana · latest 90 days of OSHA records

82employers cited

Get notified the morning OSHA posts each new citation in Indiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Indiana

Checking a subcontractor, a client or your own company? Watch Styline Diesel Service Center Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342853058 OPENED DEC 6, 2017Closed

Fatality or catastrophe · Partial · Health · 25 employees at the site · Closed Apr 6, 2018

212 W 6th Street, Huntingburg, IN 47542 · General Automotive Repair · OSHA's record · Phone and website on Google Maps

Incident on Nov 26, 2017 (fatal): Employee is killed in flash fire while cleaning with solvent

On November 26, 2017, an employee was cleaning the walls of a service pit using a solvent cleaner when a flash fire from solvent vapors occured in the service pit and engulfed the employee causing burns to the upper torso. The employee was killed.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(e)(3)(v)(a) · Flammable liquids
Serious$7,000$5,000Jan 19, 2018Final

Inspection 108564501 OPENED JUN 7, 1996Closed

Planned · No inspection · Safety · 22 employees at the site · Closed Jun 17, 1996

106 W 6th St, Huntingburg, IN 47542 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 125391375 OPENED DEC 20, 1995Closed

Planned · Complete · Safety · 19 employees at the site · Closed Jan 31, 1996

106 W 6th St, Huntingburg, IN 47542 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Other-than-serious$0$0Jan 16, 1996Closed
Citation 1, item 2
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0Jan 16, 1996Closed
Citation 1, item 3
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Jan 16, 1996Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(3)(v)(a)

(v) Ventilation—(a) Areas as defined in paragraph (e)(3)(i) of this section using Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be ventilated at a rate of not less than 1 cubic foot per minute per square foot of solid floor area. This shall be accomplished by natural or mechanical ventilation with discharge or exhaust to a safe location outside of the building. Provision shall be made for introduction of makeup air in such a manner as not to short circuit the ventilation. Ventilation shall be arranged to include all floor areas or pits where flammable vapors may collect.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.157(e)(3)

(3) The employer shall assure that portable fire extinguishers are subjected to an annual maintenance check. Stored pressure extinguishers do not require an internal examination. The employer shall record the annual maintenance date and retain this record for one year after the last entry or the life of the shell, whichever is less. The record shall be available to the Assistant Secretary upon request.

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.215(b)(9)

(9) Exposure adjustment. Safety guards of the types described in subparagraphs (3) and (4) of this paragraph, where the operator stands in front of the opening, shall be constructed so that the peripheral protecting member can be adjusted to the constantly decreasing diameter of the wheel. The maximum angular exposure above the horizontal plane of the wheel spindle as specified in paragraphs (b) (3) and (4) of this section shall never be exceeded, and the distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top shall never exceed one-fourth inch. (See Figures O-18, O-19, O-20, O-21, O-22, and O-23.)

29 CFR 1910.305 · Electrical wiring methods

Other general automotive repair employers in Indiana

Alert subscribers get notified of each newly cited employer in Indiana the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.