OSHA SearchOSHA records by employer

Sublime Restoration Company: OSHA inspections and violations

West New York, New Jersey · Masonry Contractors · NAICS 238140

1inspections
3citation items
$8,400current penalties
Mar 16, 2015last inspection

OSHA has inspected Sublime Restoration Company once in New Jersey.

The inspection began on Mar 16, 2015 after a complaint, in West New York.

That inspection ended with 3 citation items: 3 serious.

Penalties were first proposed at $8,400 and still stand at $8,400.

Scaffolds, general requirements comes up most often in these citations: 2 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Sublime Restoration Company averages $8,400 (1 cited inspection).

Sublime Restoration Company: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

New Jersey · latest 90 days of OSHA records

274employers cited

9 of them in the same industry

Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Jersey

Checking a subcontractor, a client or your own company? Watch Sublime Restoration Company and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340477694 OPENED MAR 16, 2015Closed

Complaint · Partial · Safety · 8 employees at the site · Closed Dec 26, 2018

5915 Blvd East, West New York, NJ 07093 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$2,800$2,800Apr 10, 2015Final
Citation 1, item 2
29 CFR 1926.451(g)(3)(i) · Scaffolds, general requirements
Serious$2,800$2,800Apr 10, 2015Final
Citation 1, item 3
29 CFR 1926.451(h)(2)(ii) · Scaffolds, general requirements
Serious$2,800$2,800Apr 10, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.416(a)(1)

(a) Protection of employees. (1) No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(g)(3)(i)

(i) When vertical lifelines are used, they shall be fastened to a fixed safe point of anchorage, shall be independent of the scaffold, and shall be protected from sharp edges and abrasion. Safe points of anchorage include structural members of buildings, but do not include standpipes, vents, other piping systems, electrical conduit, outrigger beams, or counterweights.

29 CFR 1926.451(h)(2)(ii)

(ii) A toeboard shall be erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below, except on float (ship) scaffolds where an edging of 3/4 × 1 1/2 inch (2 × 4 cm) wood or equivalent may be used in lieu of toeboards;