Suburban Propane LP has 2 OSHA inspections on record in Indiana, the first in 1987.
OSHA's last visit started on Jan 3, 2018 on a referral, in Nashville.
Across those inspections OSHA issued 2 citation items: 1 serious and 1 other-than-serious.
OSHA proposed $2,865 in penalties. After settlements and reviews the total is $2,625, down 8%.
For context, across all retail employers the median penalty per cited inspection since 2015 is $2,135. Suburban Propane LP averages $2,625 over 1 cited inspection in that time.
1 inspection on this page followed a fatal incident.
Citation items per year, by inspection date.
Indiana · latest 90 days of OSHA records
78employers cited
Get notified the morning OSHA posts each new citation in Indiana: the employer, the site address, the rules broken and the penalty.
OSHA records show Suburban Propane LP at 39 sites in 6 states. Together they've had 45 inspections and $50,697 in current penalties.
We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.
Included with any plan: the site-by-site record for all 39 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.
Incident on Aug 10, 1987 (fatal): One employee killed, one burned in propane gas explosion
Employee #1 drove around Building 23 to a propane truck where Employee #2 was at tempting to control a leak that had developed during the transfer of lpg from a 2,600 gallon bulk tank to 8 gallon forklift cylinders. A fire ensued and Employe e #1, who had been unaware of the situation, suffered multiple burns over 95 per cent of his body and died. Employee #2 suffered multiple burns over 45 percent o f his body and was hospitalized. The equipment involved included a semi-bobtail, a propane bulk truck, and forklift cylinders. The factors causing the accident included a propane leak and a source of ignition; the specific sources for these two factors are not clear but may be attributed to an automatic bypass system a nd a running vehicle, respectively.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.110 · Storage and handling of liquefied petroleum gases
29 CFR 1910.110(b)(14)(iv)
(iv) Gas or liquid shall not be vented to the atmosphere to assist in transferring contents of one container to another, except as provided in paragraph (e)(5)(iv) of this section and except that this shall not preclude the use of listed pump utilizing LP-Gas in the vapor phase as a source of energy and venting such gas to the atmosphere at a rate not to exceed that from a No. 31 drill size opening and provided that such venting and liquid transfer shall be located not less than 50 feet from the nearest important building.
29 CFR 1910.132 · Personal protective equipment, general requirements
29 CFR 1910.132(d)(1)(iii)
(iii) Select PPE that properly fits each affected employee.
Alert subscribers get notified of each newly cited employer in Indiana the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.