OSHA SearchOSHA records by employer

Sudberry Electrical Inc.: OSHA inspections and violations

Mcdonough, Georgia · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

5inspections
3citation items
$1,081current penalties
Oct 25, 2024last inspection

Since 2008, OSHA inspectors have visited Sudberry Electrical Inc. in Georgia 5 times.

The most recent inspection opened on Oct 25, 2024, in Sugar Hill.

In all, OSHA issued 3 citation items: 2 serious and 1 other-than-serious.

The proposed penalties came to $1,175; today they stand at $1,081, 8% less.

The rule cited most here is 1926.403 (electrical equipment on job sites), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Sudberry Electrical Inc. averages $0 across 1 cited inspection.

Sudberry Electrical Inc.: OSHA citation items per year, 2008 to 2024
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

145employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Sudberry Electrical Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347853947 OPENED OCT 25, 2024Closed

Unprogrammed other · Complete · Safety · 4 employees at the site · Closed Jan 10, 2025

1100 Peachtree Industrial Blvd, Sugar Hill, GA 30518 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(b)(1) · Electrical equipment on job sites
Other-than-serious$0$0Dec 2, 2024Final

Inspection 346213168 OPENED SEP 9, 2022Closed

Planned · No inspection · Safety · 9 employees at the site · Closed Dec 8, 2022

50 Executive Park South, Brookhaven, GA 30329 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 346169907 OPENED AUG 24, 2022Closed

Unprogrammed other · Partial · Safety · 8 employees at the site · Closed Aug 29, 2022

1670 Friendship Road, Hoschton, GA 30548 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 312526841 OPENED MAY 14, 2009Closed

Planned · Partial · Safety · 1 employee at the site · Closed Nov 27, 2009

2529 Peachwood Circle, Ne, Atlanta, GA 30345 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Serious$800$800Jun 26, 2009Closed

Inspection 311037733 OPENED FEB 8, 2008Closed

Unprogrammed other · Partial · Safety · 2 employees at the site · Closed Mar 25, 2008

01 Pioneer Parkway, Mcdonough, GA 30253 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$375$281Mar 7, 2008Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(1)

(b) Examination, installation, and use of equipment—(1) Examination. The employer shall ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees. Safety of equipment shall be determined on the basis of the following considerations:

29 CFR 1926.403(b)(2)

(2) Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(i)

(b) Branch circuits—(1) Ground-fault protection—(i) General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.

Other electrical contractors and other wiring installation contractors employers in Georgia

Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.