OSHA SearchOSHA records by employer

Suenos Construction Inc: OSHA inspections and violations

Mahwah, New Jersey · Siding Contractors · NAICS 238170

1inspections
3citation items
$11,640current penalties
Jul 2, 2018last inspection

OSHA has inspected Suenos Construction Inc once in New Jersey.

The inspection began on Jul 2, 2018 as a planned inspection, in Mahwah.

That inspection ended with 3 citation items: 3 serious.

Penalties were first proposed at $11,640 and still stand at $11,640.

Scaffolds, general requirements comes up most often in these citations: 2 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Suenos Construction Inc averages $11,640 (1 cited inspection).

Suenos Construction Inc: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

New Jersey · latest 90 days of OSHA records

270employers cited

6 of them in the same industry

Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Jersey

Checking a subcontractor, a client or your own company? Watch Suenos Construction Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343275160 OPENED JUL 2, 2018Closed

Planned · Partial · Safety · 5 employees at the site · Closed Mar 28, 2023

Masonicus Road, Mahwah, NJ 07430 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$3,880$3,880Aug 9, 2018Final
Citation 1, item 2
29 CFR 1926.451(f)(6) · Scaffolds, general requirements
Serious$3,880$3,880Aug 9, 2018Final
Citation 1, item 3
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$3,880$3,880Aug 9, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(f)(6)

(6) The clearance between scaffolds and power lines shall be as follows: Scaffolds shall not be erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer to exposed and energized power lines than as follows:

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.452(j)(2)

(2) Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled.