OSHA SearchOSHA records by employer

Summit Construction: OSHA inspections and violations

Chicago, Illinois · Masonry Contractors · NAICS 238140

1inspections
7citation items
$3,500current penalties
Apr 22, 2015last inspection

OSHA inspectors have visited Summit Construction in Illinois one time.

It opened on Apr 22, 2015 as a planned inspection, in Chicago.

In all, OSHA issued 7 citation items: 7 serious.

The proposed penalties came to $5,600; today they stand at $3,500, 38% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 6 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Summit Construction averages $3,500 across 1 cited inspection.

Summit Construction: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Illinois · latest 90 days of OSHA records

413employers cited

11 of them in the same industry

Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Illinois

Checking a subcontractor, a client or your own company? Watch Summit Construction and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340585108 OPENED APR 22, 2015Closed

Planned · Partial · Safety · 4 employees at the site · Closed Jul 25, 2016

1501 N. Talman, Chicago, IL 60622 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(d)(3)(vi) · Scaffolds, general requirements
Serious$2,800$1,750Jun 10, 2015Final
Citation 1, item 1b
29 CFR 1926.451(d)(16) · Scaffolds, general requirements
Serious$0$0Jun 10, 2015Final
Citation 1, item 1c
29 CFR 1926.451(d)(17) · Scaffolds, general requirements
Serious$0$0Jun 10, 2015Final
Citation 1, item 1d
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Jun 10, 2015Final
Citation 1, item 2a
29 CFR 1926.451(g)(1)(ii) · Scaffolds, general requirements
Serious$2,800$1,750Jun 10, 2015Final
Citation 1, item 2b
29 CFR 1926.451(g)(3)(i) · Scaffolds, general requirements
Serious$0$0Jun 10, 2015Final
Citation 1, item 2c
29 CFR 1926.502(d)(16)(iii) · Fall protection systems
Serious$0$0Jun 10, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(d)(16)

(16) In addition to the normal operating brake, suspension scaffold power-operated hoists and manually operated hoists shall have a braking device or locking pawl which engages automatically when a hoist makes either of the following uncontrolled movements: an instantaneous change in momentum or an accelerated overspeed.

29 CFR 1926.451(d)(17)

(17) Manually operated hoists shall require a positive crank force to descend.

29 CFR 1926.451(d)(3)(vi)

(vi) Outrigger beams which are not stabilized by bolts or other direct connections to the floor or roof deck shall be secured by tiebacks.

29 CFR 1926.502 · Fall protection systems

Other masonry contractors employers in Illinois

Alert subscribers get notified of each newly cited employer in Illinois the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.