Summit Construction, Inc.: OSHA inspections and violations

Chesapeake, Virginia · New Single-Family Housing Construction (except For-Sale Builders) · NAICS 236115

5inspections
9citation items
$6,399current penalties
Oct 27, 2025last inspection

Summit Construction, Inc. has 5 OSHA inspections on record in Virginia, the first in 2007.

OSHA's last visit started on Oct 27, 2025 as a planned inspection, in Winchester.

Across those inspections OSHA issued 9 citation items: 5 serious and 4 other-than-serious.

OSHA proposed $9,962 in penalties. After settlements and reviews the total is $6,399, down 36%.

Most often, OSHA cited 1926.501, fall protection in construction (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,079. Summit Construction, Inc. averages $3,200 over 2 cited inspections in that time.

Summit Construction, Inc.: OSHA citation items per year, 2007 to 2025
Citation items per year, by inspection date.

Want to know if OSHA cites Summit Construction, Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 348572926 OPENED OCT 27, 2025Closed

Planned · Complete · Safety · 10 employees at the site · Closed Dec 9, 2025

1834 Purpose Dr., Winchester, VA 22601 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343546370 OPENED OCT 19, 2018Closed

Planned · Partial · Safety · 1 employee at the site · Closed Feb 12, 2019

Autumn Woods Townhome Community Sikeston Lane, Chesapeake, VA 23322 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.25(a) · Housekeeping
Other-than-serious$600$0Jan 16, 2019Final
Citation 1, item 2a
29 CFR 1926.50(c) · Medical services and first aid
Serious$600$600Jan 16, 2019Final
Citation 1, item 3
29 CFR 1926.150(c)(1)(i) · Fire protection
Other-than-serious$600$0Jan 16, 2019Final
Citation 1, item 5
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$600$600Jan 16, 2019Final

Inspection 341183838 OPENED JAN 13, 2016Closed

Planned · Complete · Safety · 7 employees at the site · Closed Mar 14, 2016

523 Carpenter Road, Fort Myer, VA 22211 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.350(f)(4) · Gas welding and cutting
Serious$2,380$1,785Mar 4, 2016Final
Citation 1, item 2
29 CFR 1926.350(j) · Gas welding and cutting
Serious$2,023$1,517Mar 4, 2016Final
Citation 1, item 3
29 CFR 1926.501(b)(3) · Fall protection in construction
Serious$2,529$1,897Mar 4, 2016Final

Inspection 317367076 OPENED OCT 24, 2013Closed

Planned · Partial · Safety · 10 employees at the site · Closed Dec 5, 2013

Lot 22 Tyler Way, Chesapeake, VA 23322 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR CSAN0051 C03
Other-than-serious$315$0Nov 12, 2013Closed
Citation 1, item 2
29 CFR 1926.150(c)(1)(iv) · Fire protection
Other-than-serious$315$0Nov 12, 2013Closed

Inspection 311092589 OPENED APR 24, 2007Closed

Planned · Partial · Safety · 6 employees at the site · Closed Apr 24, 2007

Lot 228 Avery Way, Virginia Beach, VA 23464 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(c)(1)(i)

(c) Portable firefighting equipment—(1) Fire extinguishers and small hose lines. (i) A fire extinguisher, rated not less than 2A, shall be provided for each 3,000 square feet of the protected building area, or major fraction thereof. Travel distance from any point of the protected area to the nearest fire extinguisher shall not exceed 100 feet.

29 CFR 1926.150(c)(1)(iv)

(iv) One or more fire extinguishers, rated not less than 2A, shall be provided on each floor. In multistory buildings, at least one fire extinguisher shall be located adjacent to stairway.

29 CFR 1926.25 · Housekeeping

29 CFR 1926.25(a)

(a) During the course of construction, alteration, or repairs, form and scrap lumber with protruding nails, and all other debris, shall be kept cleared from work areas, passageways, and stairs, in and around buildings or other structures.

29 CFR 1926.350 · Gas welding and cutting

29 CFR 1926.50 · Medical services and first aid

29 CFR 1926.501 · Fall protection in construction

Other new single-family housing construction (except for-sale builders) employers in Virginia

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.