Sun Chemical Corporation has one OSHA inspection on record in Delaware.
OSHA opened it on Feb 7, 2022 on a referral, in Newport.
From that inspection OSHA issued 3 citation items: 3 serious.
OSHA proposed $43,506 in penalties. After settlements and reviews the total is $30,455, down 30%.
Most often, OSHA cited 1910.147, lockout/tagout (3 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Sun Chemical Corporation averages $30,455 over 1 cited inspection in that time.
Sun Chemical Corporation also files yearly injury logs with OSHA, summarized below.
It reported 2 severe injuries to OSHA since 2015.
Citation items per year, by inspection date.
Delaware · latest 90 days of OSHA records
32employers cited
Get notified the morning OSHA posts each new citation in Delaware: the employer, the site address, the rules broken and the penalty.
OSHA records show Sun Chemical Corporation at 18 sites in 6 states. Together they've had 79 inspections and $499,583 in current penalties.
We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.
Included with any plan: the site-by-site record for all 18 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.
Incident on Jan 30, 2022: Employee amputates finger when reaching into rotating valve
At 12:50 p.m. on January 30, 2022, an employee was working on the ground finishing the connection of a tote-sized sac of crystalline chemical to an Iris process feed chute. The crystals feed by gravity down the chute through the Iris and then through a rotating vane valve. There are two panels (ports) covering the vane valve. According to a coworker (EH&S Manager), operators are not instructed to remove the ports during the process. Apparently, the sac emptied into the chute only halfway before the chemical got struck and blocked the chute bottom and/or side walls and/or within the vane valve. The employee reported that he opened one of the panels and reached in with his right hand to see if he could unclog the system. The employee was struck by the vane valve as a result. The employee amputated his index finger to the first knuckle. The employer's onsite response team (fire brigade) responded to a "code blue" and provided first aid to the employee, who was transported to the hospital for emergency medical care. The employee was discharged from the hospital at 8:00 pm on the same day.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Newport site logged 2 recordable injuries or illnesses among about 124 workers: 1.6 per 100 full-time workers, against a median of 0.7 for its industry. Those cases cost 109 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Sun Chemical
Newport · 2025
124
2
1
1.6
0.7
Colors and Effects USA LLC
Newport · 2022
155
2
1
1.3
0.7
Included with any plan: 1 more yearly log from these sites, back to 2021, with each site's average rate over its latest three years. Already a subscriber? Sign in.
Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 2 reports on file.
Jul 11, 2024, Newport: Hospitalization · effects of poison, toxic, or allergenic exposure unspecified · body systems
An employee connected a hose from a chemical tank car containing about 34,000 pounds of aniline to a dripless connection, then actuated the pumping system to transfer the aniline (Aminobenzene) into an onsite holding vessel. The employee was splashed with aniline while disconnecting the transfer hose after the tank car was fully emptied. The employee's right thigh was contaminated with aniline;…
An employee was working to connect a tote-size sac of crystalline chemical to the iris of a process feed chute. The crystals feed down the chute through the iris, then through a rotating vane valve. There are two panels covering the vane valve. The sac of crystalline chemical emptied down the chute just halfway before the crystalline chemical got blocked. The employee opened the panel covering…
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
(ii) The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:
29 CFR 1910.147(c)(7)(i)
(7) Training and communication. (i) The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following:
29 CFR 1910.147(d)
(d) Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence:
Other synthetic dye and pigment manufacturing employers in Delaware
Alert subscribers get notified of each newly cited employer in Delaware the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.