OSHA SearchOSHA records by employer

Sunbelt Chemicals Corp.: OSHA inspections and violations

Palm Coast, Florida · Other Chemical and Allied Products Merchant Wholesalers · NAICS 424690

3inspections
14citation items
$5,749current penalties
Sep 28, 2015last inspection

Sunbelt Chemicals Corp. has 3 OSHA inspections on record in Florida, the first in 1997.

OSHA's last visit started on Sep 28, 2015 after a complaint, in Palm Coast.

Across those inspections OSHA issued 14 citation items: 12 serious and 2 other-than-serious.

OSHA proposed $8,269 in penalties. After settlements and reviews the total is $5,749, down 30%.

Most often, OSHA cited 1910.305, electrical wiring methods (3 items).

For context, across all wholesale employers the median penalty per cited inspection since 2015 is $3,424. Sunbelt Chemicals Corp. averages $3,780 over 1 cited inspection in that time.

It reported 1 severe injury to OSHA since 2015.

Sunbelt Chemicals Corp.: OSHA citation items per year, 1997 to 2015
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

318employers cited

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Sunbelt Chemicals Corp. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340947316 OPENED SEP 28, 2015Closed

Complaint · Partial · Health · 30 employees at the site · Closed Oct 27, 2015

71 Hargrove Grade, Palm Coast, FL 32137 · Other Chemical and Allied Products Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340948850 OPENED SEP 28, 2015Closed

Complaint · Partial · Safety · 30 employees at the site · Closed Nov 23, 2015

71 Hargrove Grade, Palm Coast, FL 32137 · Other Chemical and Allied Products Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$4,410$2,646Oct 28, 2015Final
Citation 1, item 2a
29 CFR 1910.305(b)(1)(i) · Electrical wiring methods
Serious$1,890$1,134Oct 28, 2015Final
Citation 1, item 2b
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$0$0Oct 28, 2015Final

Inspection 301019071 OPENED JUN 25, 1997Closed

Referral · Partial · Health · 60 employees at the site · Closed Sep 22, 1997

71 Hargrove Grade, Palm Coast, FL 32137 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$394$394Jul 8, 1997Closed
Citation 1, item 2a
29 CFR 1910.151(c) · First aid and eyewash
Serious$394$394Jul 8, 1997Closed
Citation 1, item 2b
29 CFR 1910.158(c)(2) · Standpipe and hose systems
Serious$0$0Jul 8, 1997Closed
Citation 1, item 2c
29 CFR 1910.303(g)(1)(i) · Electrical equipment, general requirements
Serious$0$0Jul 8, 1997Closed
Citation 1, item 2d
29 CFR 1910.22(b)(2) · General requirements
Serious$0$0Jul 8, 1997Closed
Citation 1, item 3a
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$394$394Jul 8, 1997Closed
Citation 1, item 3b
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Jul 8, 1997Closed
Citation 1, item 4
29 CFR 1910.243(b)(2) · Guarding of portable powered tools
Serious$394$394Jul 8, 1997Closed
Citation 1, item 5
29 CFR 1910.305(b)(2) · Electrical wiring methods
Serious$394$394Jul 8, 1997Closed
Citation 2, item 1
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Jul 8, 1997Closed
Citation 2, item 2
29 CFR 1910.23(c)(3) · Guarding floor and wall openings and holes
Other-than-serious$0$0Jul 8, 1997Closed

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Feb 21, 2020, Palm Coast: Hospitalization, amputation · amputations · foot (feet), n.e.c.

An employee was reaching with a push stick to adjust an empty plastic bottle that was stuck about 14 feet overhead. A forklift backed out of an 18-wheeler trailer and struck the employee's right leg, breaking it. The employee was hospitalized and the employee's right foot was medically amputated.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(6)(ii)

(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.151(c)

(c) Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use.

29 CFR 1910.158 · Standpipe and hose systems

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.215(a)(4)

(4) Work rests. On offhand grinding machines, work rests shall be used to support the work. They shall be of rigid construction and designed to be adjustable to compensate for wheel wear. Work rests shall be kept adjusted closely to the wheel with a maximum opening of one-eighth inch to prevent the work from being jammed between the wheel and the rest, which may cause wheel breakage. The work rest shall be securely clamped after each adjustment. The adjustment shall not be made with the wheel in motion.

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.243 · Guarding of portable powered tools

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

Other other chemical and allied products merchant wholesalers employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.