OSHA SearchOSHA records by employer

Sunbright - City Hall: OSHA inspections and violations

Sunbright, Tennessee · Executive Offices · NAICS 921110

11inspections
9citation items
$0current penalties
Apr 7, 2026last inspection

OSHA has inspected Sunbright - City Hall 11 times in Tennessee since 2005.

The latest one began on Apr 7, 2026 as a planned inspection, in Sunbright.

Those inspections ended with 9 citation items: 9 serious.

None of the citations carried a penalty.

Electrical wiring methods comes up most often in these citations: 4 items under 1910.305.

How that compares: the median penalty per cited inspection for public administration employers since 2015 is $0, and Sunbright - City Hall averages $0 (4 cited inspections).

Sunbright - City Hall: OSHA citation items per year, 2005 to 2026
Citation items per year, by inspection date.

Tennessee · latest 90 days of OSHA records

334employers cited

9 of them in the same industry

Get notified the morning OSHA posts each new citation in Tennessee: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Tennessee

Checking a subcontractor, a client or your own company? Watch Sunbright - City Hall and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348869983 OPENED APR 7, 2026Closed

Planned · Complete · Health · Local government · 2 employees at the site · Closed Apr 15, 2026

120 Melton Drive, Sunbright, TN 37872 · Executive Offices · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 346241599 OPENED SEP 21, 2022Closed

Planned · Complete · Safety · Local government · 1 employee at the site · Closed Oct 19, 2022

120 Melton Drive, Sunbright, TN 37872 · Executive Offices · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Serious$0$0Sep 28, 2022Final
Citation 1, item 2
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$0$0Sep 28, 2022Final

Inspection 345057376 OPENED DEC 8, 2020Closed

Planned · Complete · Safety · Local government · 1 employee at the site · Closed Jan 5, 2021

120 Melton Drive, Sunbright, TN 37872 · Executive Offices · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.37(b)(5) · Exit routes
Serious$0$0Dec 16, 2020Final
Citation 1, item 2
29 CFR 1910.305(a)(2)(x) · Electrical wiring methods
Serious$0$0Dec 16, 2020Final

Inspection 343947917 OPENED APR 22, 2019Closed

Planned · Complete · Safety · Local government · 3 employees at the site · Closed May 8, 2019

120 Melton Drive, Sunbright, TN 37872 · Executive Offices · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.36(d)(1) · Exit route design
Serious$0$0Apr 30, 2019Final
Citation 1, item 2
29 CFR 1910.37(a)(3) · Exit routes
Serious$0$0Apr 30, 2019Final
Citation 1, item 3
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$0$0Apr 30, 2019Final

Inspection 342351897 OPENED MAY 25, 2017Closed

Planned · Complete · Safety · Local government · 11 employees at the site · Closed Jun 2, 2017

120 Melton Drive, Sunbright, TN 37872 · Executive Offices · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340835974 OPENED AUG 10, 2015Closed

Planned · Complete · Safety · Local government · 11 employees at the site · Closed Sep 14, 2015

120 Metlton Drive, Sunbright, TN 37872 · Executive Offices · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(a)(1) · General requirements
Serious$0$0Aug 20, 2015Final

Inspection 317316289 OPENED AUG 26, 2013Closed

Planned · Complete · Safety · Local government · 11 employees at the site · Closed Aug 26, 2013

120 Melton Drive, Sunbright, TN 37872 · Executive Offices · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 316259662 OPENED DEC 9, 2011Closed

Planned · Complete · Safety · Local government · 11 employees at the site · Closed Dec 9, 2011

120 Melton Drive, Sunbright, TN 37872 · Executive Offices · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

3 older inspections

Inspection 314126319 OPENED FEB 26, 2010Closed

Planned · Complete · Safety · Local government · 11 employees at the site · Closed Apr 26, 2010

120 Melton Drive, Sunbright, TN 37872 · Executive Offices · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(b)(1)(i) · Electrical wiring methods
Serious$0$0Mar 26, 2010Closed

Inspection 309929362 OPENED JUN 20, 2006Closed

Planned · Complete · Safety · Local government · 2 employees at the site · Closed Jun 20, 2006

120 Melton Drive, Sunbright, TN 37872 · Executive Offices · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 309231751 OPENED SEP 27, 2005Closed

Planned · No inspection · Safety · Local government · Closed Sep 27, 2005

120 Melton Drive, Sunbright, TN 37872 · Other General Government Support · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.22 · General requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.304(g)(5)

(5) Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent, continuous, and effective.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(a)(2)(x)

(x) Flexible cords and cables shall be protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points.

29 CFR 1910.305(b)(1)(i)

(b) Cabinets, boxes, and fittings—(1) Conductors entering boxes, cabinets, or fittings. (i) Conductors entering cutout boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed.

29 CFR 1910.36 · Exit route design

29 CFR 1910.37 · Exit routes

Other executive offices employers in Tennessee

Alert subscribers get notified of each newly cited employer in Tennessee the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.