Sundance Meadows Inc: OSHA inspections and violations

Bend, Oregon · Beef Cattle Ranching and Farming · NAICS 112111

3inspections
9citation items
$600current penalties
Mar 31, 2016last inspection

Sundance Meadows Inc has 3 OSHA inspections on record in Oregon, the first in 2008.

OSHA's last visit started on Mar 31, 2016 as a planned inspection, in Bend.

Across those inspections OSHA issued 9 citation items: 6 serious and 3 other-than-serious.

OSHA proposed $600 in penalties and the amount has not been reduced.

Most often, OSHA cited 1910.305, electrical wiring methods (2 items).

For context, across all farming, fishing and forestry employers the median penalty per cited inspection since 2015 is $1,440. Sundance Meadows Inc averages $600 over 1 cited inspection in that time.

Sundance Meadows Inc: OSHA citation items per year, 2008 to 2016
Citation items per year, by inspection date.

Oregon · latest 90 days of OSHA records

386employers cited

Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oregon

Checking a subcontractor, a client or your own company? Watch Sundance Meadows Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341375335 OPENED MAR 31, 2016Closed

Planned · Complete · Safety · 5 employees at the site · Closed Sep 14, 2016

60335 Arnold Market Rd, Bend, OR 97702 · Beef Cattle Ranching and Farming · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.110(h)(6)(ii)(b) · Storage and handling of liquefied petroleum gases
Serious$100$100May 17, 2016Final
Citation 1, item 2
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$100$100May 17, 2016Final
Citation 1, item 3
29 CFR 1910.23(d)(1)(ii) · Guarding floor and wall openings and holes
Serious$100$100May 17, 2016Final
Citation 1, item 4
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$100$100May 17, 2016Final
Citation 1, item 5
29 CFR OAR 437-002-0210(2)(A)
Serious$100$100May 17, 2016Final
Citation 1, item 6
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$100$100May 17, 2016Final
Citation 2, item 7
29 CFR 1910.305(a)(2)(i) · Electrical wiring methods
Other-than-serious$0$0May 17, 2016Final
Citation 2, item 8
29 CFR 1910.304(a)(2) · Grounding and circuit protection
Other-than-serious$0$0May 17, 2016Final
Citation 2, item 9
29 CFR OAR 437-001-0765(13)-1
Other-than-serious$0$0May 17, 2016Final

Inspection 313460552 OPENED SEP 30, 2009Closed

Planned · No inspection · Safety · Closed Sep 30, 2009

60335 Arnold Market Rd, Bend, OR 97702 · Beef Cattle Ranching and Farming · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 312261712 OPENED SEP 29, 2008Closed

Planned · No inspection · Safety · Closed Sep 29, 2008

875 Se Third St Ste 200, Bend, OR 97702 · Beef Cattle Ranching and Farming · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.110 · Storage and handling of liquefied petroleum gases

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.219(e)(1)(i)

(e) Belt, rope, and chain drives—(1) Horizontal belts and ropes. (i) Where both runs of horizontal belts are seven (7) feet or less from the floor level, the guard shall extend to at least fifteen (15) inches above the belt or to a standard height except that where both runs of a horizontal belt are 42 inches or less from the floor, the belt shall be fully enclosed in accordance with paragraphs (m) and (o) of this section.

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.304(a)(2)

(2) Polarity of connections. No grounded conductor may be attached to any terminal or lead so as to reverse designated polarity.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(a)(2)(i)

(i) Temporary electrical power and lighting installations of 600 volts, nominal, or less may be used only as follows: