OSHA SearchOSHA records by employer

Sung K Sue: OSHA inspections and violations

Glen Burnie, Maryland · Siding Contractors · NAICS 238170

1inspections
8citation items
$1,050current penalties
Oct 15, 2020last inspection

OSHA has inspected Sung K Sue once in Maryland.

The inspection began on Oct 15, 2020 on a referral, in Glen Burnie.

That inspection ended with 8 citation items: 8 serious.

Penalties were first proposed at $1,050 and still stand at $1,050.

Scaffolds, general requirements comes up most often in these citations: 6 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Sung K Sue averages $1,050 (1 cited inspection).

Sung K Sue: OSHA citation items per year, 2020 to 2020
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

194employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Sung K Sue and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344978812 OPENED OCT 15, 2020Closed

Referral · Complete · Safety · 3 employees at the site · Closed Apr 8, 2021

Lot #34 Safe Harbor Court, Glen Burnie, MD 21060 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$1,050$1,050Jan 21, 2021Final
Citation 1, item 1b
29 CFR 1926.451(b)(3) · Scaffolds, general requirements
Serious$0$0Jan 21, 2021Final
Citation 1, item 1c
29 CFR 1926.451(b)(5)(ii) · Scaffolds, general requirements
Serious$0$0Jan 21, 2021Final
Citation 1, item 1d
29 CFR 1926.451(c)(2)(i) · Scaffolds, general requirements
Serious$0$0Jan 21, 2021Final
Citation 1, item 1e
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0Jan 21, 2021Final
Citation 1, item 1f
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$0$0Jan 21, 2021Final
Citation 1, item 1g
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Jan 21, 2021Final
Citation 1, item 1h
29 CFR 1926.454(b) · Scaffold training
Serious$0$0Jan 21, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(2)

(2) Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and walkway shall be at least 18 inches (46 cm) wide.

29 CFR 1926.451(b)(3)

(3) Except as provided in paragraphs (b)(3) (i) and (ii) of this section, the front edge of all platforms shall not be more than 14 inches (36 cm) from the face of the work, unless guardrail systems are erected along the front edge and/or personal fall arrest systems are used in accordance with paragraph (g) of this section to protect employees from falling.

29 CFR 1926.451(b)(5)(ii)

(ii) Each platform greater than 10 feet in length shall not extend over its support more than 18 inches (46 cm), unless it is designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end.

29 CFR 1926.454 · Scaffold training

Other siding contractors employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.