OSHA SearchOSHA records by employer

Sunlight Construction AA LLC: OSHA inspections and violations

Brooklyn, New York · Commercial and Institutional Building Construction · NAICS 236220

8inspections
12citation items
$40,850current penalties
May 6, 2021last inspection

Since 2018, OSHA inspectors have visited Sunlight Construction AA LLC in New York 8 times.

The most recent inspection opened on May 6, 2021 after a complaint, in Flushing.

In all, OSHA issued 12 citation items: 11 serious and 1 repeat.

The proposed penalties came to $62,643; today they stand at $40,850, 35% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 5 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Sunlight Construction AA LLC averages $6,808 across 6 cited inspections.

Sunlight Construction AA LLC: OSHA citation items per year, 2018 to 2021
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

359employers cited

13 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Sunlight Construction AA LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345291744 OPENED MAY 6, 2021Closed

Complaint · Partial · Safety · 32 employees at the site · Closed Jun 7, 2022

136-18/20 Maple Ave, Flushing, NY 11355 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.502(i)(3) · Fall protection systems
Serious$5,461$3,300Sep 21, 2021Final

Inspection 344064175 OPENED JUN 6, 2019Closed

Planned · Partial · Safety · 5 employees at the site · Closed Oct 24, 2019

8315 13th Avenue, Brooklyn, NY 11228 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343918918 OPENED APR 9, 2019Closed

Planned · Partial · Safety · 5 employees at the site · Closed Oct 3, 2019

673 56th Street, Brooklyn, NY 11220 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(a)(2)(ii)(e) · Job-site wiring
Serious$3,334$2,000Jun 6, 2019Final

Inspection 343852554 OPENED MAR 13, 2019Closed

Planned · Partial · Safety · 4 employees at the site · Closed Sep 6, 2019

765 55th Street, Brooklyn, NY 11220 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.300(b)(1) · Tools—Hand and Power: general requirements
Serious$2,500$1,500Apr 3, 2019Final

Inspection 343816013 OPENED FEB 27, 2019Closed

Planned · Partial · Safety · 3 employees at the site · Closed Feb 4, 2022

921 57th Street, Brooklyn, NY 11219 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$5,835$3,367Jun 6, 2019Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$5,835$3,367Jun 6, 2019Final
Citation 1, item 3
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$5,835$3,367Jun 6, 2019Final
Citation 2, item 1
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Repeat$11,669$9,699Jun 6, 2019Final

Inspection 343228763 OPENED JUN 14, 2018Closed

Planned · Partial · Safety · 20 employees at the site · Closed Jan 9, 2020

521 45th Street, Brooklyn, NY 11220 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Serious$2,956$1,456Dec 13, 2018Final
Citation 1, item 2
29 CFR 1926.403(e) · Electrical equipment on job sites
Serious$3,696$2,196Dec 13, 2018Final
Citation 1, item 3
29 CFR 1926.403(i)(2)(i) · Electrical equipment on job sites
Serious$5,174$3,674Dec 13, 2018Final
Citation 1, item 4
29 CFR 1926.405(a)(2)(ii)(e) · Job-site wiring
Serious$5,174$3,674Dec 13, 2018Final

Inspection 343209078 OPENED JUN 6, 2018Closed

Planned · Partial · Safety · 11 employees at the site · Closed Jun 12, 2018

832 40th St, Brooklyn, NY 11232 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343091161 OPENED APR 6, 2018Closed

Complaint · Complete · Safety · 20 employees at the site · Closed May 16, 2019

4112 8th Ave, Brooklyn, NY 11232 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$5,174$3,250Sep 27, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.300 · Tools—Hand and Power: general requirements

29 CFR 1926.300(b)(1)

(b) Guarding. (1) When power operated tools are designed to accommodate guards, they shall be equipped with such guards when in use.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(2)

(2) Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification.

29 CFR 1926.403(e)

(e) Splices. Conductors shall be spliced or joined with splicing devices designed for the use or by brazing, welding, or soldering with a fusible metal or alloy. Soldered splices shall first be so spliced or joined as to be mechanically and electrically secure without solder and then soldered. All splices and joints and the free ends of conductors shall be covered with an insulation equivalent to that of the conductors or with an insulating device designed for the purpose.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.502 · Fall protection systems

Other commercial and institutional building construction employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.