OSHA SearchOSHA records by employer

Sunline Energy Inc: OSHA inspections and violations

San Diego, California · Solar Electric Power Generation · NAICS 221114

2inspections
5citation items
$10,990current penalties
Dec 23, 2021last inspection

Sunline Energy Inc has 2 OSHA inspections on record in California, the first in 2020.

OSHA's last visit started on Dec 23, 2021 after an accident, in Ramona.

Across those inspections OSHA issued 5 citation items: 3 serious and 2 other-than-serious.

OSHA proposed $17,720 in penalties. After settlements and reviews the total is $10,990, down 38%.

For context, across all utility employers the median penalty per cited inspection since 2015 is $0. Sunline Energy Inc averages $5,495 over 2 cited inspections in that time.

Sunline Energy Inc: OSHA citation items per year, 2020 to 2021
Citation items per year, by inspection date.

California · latest 90 days of OSHA records

1,139employers cited

Get notified the morning OSHA posts each new citation in California: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in California

Checking a subcontractor, a client or your own company? Watch Sunline Energy Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345701619 OPENED DEC 23, 2021Closed

Accident · Partial · Safety · 75 employees at the site · Closed Oct 31, 2022

25707 Caryn Ct., Ramona, CA 92065 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 3203(A)(7)
Serious$4,385$4,385May 27, 2022Final
Citation 2, item 1
29 CFR 3328(A)
Serious$4,385$0May 27, 2022Final

Inspection 344549811 OPENED JAN 10, 2020Closed

Accident · Partial · Safety · 70 employees at the site · Closed Nov 23, 2020

10812 Sunset Ridge Dr., San Diego, CA 92131 · Solar Electric Power Generation · OSHA's record · Phone and website on Google Maps

Incident on Dec 13, 2019: Employee falls from roof and sustains head injuries

At 10:00 a.m. on December 13, 2019, two employees were cutting and installing a piece of synthetic roofing paper. Employee #1 was cutting a piece of underlayment, while a coworker was holding the other side. Employee #1 could not reach the section of the synthetic roofing paper he was trying to finish cutting, so he attempted to step over it. He stepped on top of the paper, slid along with the paper, and fell off the roof. The coworker also moved suddenly out of the way and also slid and fell. Employee #1 sustained head injuries and was admitted to the hospital for more than 24 hours. Sunline Energy, Inc. is a roofing contractor, working on a two-story residential house. The work being performed included removal and installation of roof tile.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1509(E)
Other-than-serious$485$250Jun 12, 2020Final
Citation 1, item 2
29 CFR 3395(I)
Other-than-serious$365$280Jun 12, 2020Final
Citation 2, item 1
29 CFR 3203(A)
Serious$8,100$6,075Jun 12, 2020Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

Other solar electric power generation employers in California

Alert subscribers get notified of each newly cited employer in California the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.