OSHA SearchOSHA records by employer

Sunrise Erectors, Inc.: OSHA inspections and violations

Pensacola, Florida · Other Foundation, Structure, and Building Exterior Contractors · NAICS 238190

2inspections
3citation items
$5,660current penalties
Mar 4, 2024last inspection

Since 2010, OSHA inspectors have visited Sunrise Erectors, Inc. in Florida 2 times.

The most recent inspection opened on Mar 4, 2024 on a referral, in Pensacola.

In all, OSHA issued 3 citation items: 3 serious.

The penalties, $5,660 in total, stand where OSHA first set them.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Sunrise Erectors, Inc. averages $4,610 across 1 cited inspection.

It reported 1 severe injury to OSHA since 2015.

Sunrise Erectors, Inc.: OSHA citation items per year, 2010 to 2024
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

326employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Sunrise Erectors, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347321085 OPENED MAR 4, 2024Closed

Referral · Partial · Safety · 12 employees at the site · Closed Aug 13, 2024

Bldg. 234 11000 University Parkway, Pensacola, FL 32505 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.760(c)(7) · Fall protection
Serious$4,610$4,610Jul 9, 2024Final

Inspection 313874083 OPENED JAN 13, 2010Closed

Planned · Complete · Safety · 6 employees at the site · Closed Mar 1, 2010

5659 N. 9th St, Pensacola, FL 32504 · Other Foundation, Structure, and Building Exterior Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$525$525Feb 10, 2010Closed
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$525$525Feb 10, 2010Closed

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Feb 29, 2024, Pensacola: Hospitalization · fractures and soft tissue injuries · multiple body parts n.e.c.

An employee was installing metal decking on the leading edge of a second floor and fell approximately 17.5 feet to the ground. He sustained a fractured and dislocated shoulder, a fractured right femoral head, a right hip dislocation, a pelvic fracture, three broken ribs on the right side, and a fractured left wrist.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(1)

(b)(1) Unprotected sides and edges. Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.

29 CFR 1926.760 · Fall protection

29 CFR 1926.760(c)(7)

(7) Final deck attachments and installation of shear connectors shall not be performed in the CDZ.

Other other foundation, structure, and building exterior contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.