OSHA SearchOSHA records by employer

Superior Industrial Services LLC: OSHA inspections and violations

Houston, Texas · Paint and Coating Manufacturing · NAICS 325510

1inspections
14citation items
$19,511current penalties
May 23, 2023last inspection

OSHA inspectors have visited Superior Industrial Services LLC in Texas one time.

It opened on May 23, 2023 after a fatality or catastrophe, in Houston.

In all, OSHA issued 14 citation items: 14 serious.

The proposed penalties came to $33,040; today they stand at $19,511, 41% less.

The rule cited most here is 1910.1053 (silica dust in general industry), 7 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. Superior Industrial Services LLC averages $19,511 across 1 cited inspection.

1 inspection on this page followed a fatal incident.

Superior Industrial Services LLC: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

401employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Superior Industrial Services LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346722523 OPENED MAY 23, 2023Closed

Fatality or catastrophe · Partial · Health · 18 employees at the site · Closed Feb 20, 2026

12047 Proctor Street, Houston, TX 77038 · Paint and Coating Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on May 18, 2023 (fatal): Employee passes out while spray painting in respirator, late

At 7:45 p.m. on May 18, 2023, an employee working for a paint and coating manufacturer was wearing a 3M half-face respirator while spray coating MacroPoxy 646 Fast Cure Epoxy on parts. The employee was spraying the last parts of the day when he began feeling chest pain. The employee used his inhaler twice but passed out. A coworker (supervisor) called an ambulance which took the employee to the hospital. The employee never recovered, had no brain activity and was taken off life support a week after the incident. The employee died of cardiovascular failure.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$6,250$5,000Oct 19, 2023Final
Citation 1, item 2b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Oct 19, 2023Final
Citation 1, item 2c
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Oct 19, 2023Final
Citation 1, item 2d
29 CFR 1910.134(k) · Respiratory protection
Serious$0$0Oct 19, 2023Final
Citation 1, item 3a
29 CFR 1910.134(i)(5)(iv) · Respiratory protection
Serious$4,465$2,902Oct 19, 2023Final
Citation 1, item 3b
29 CFR 1910.134(i)(7) · Respiratory protection
Serious$0$0Oct 19, 2023Final
Citation 1, item 4a
29 CFR 1910.1053(c) · Silica dust in general industry
Serious$4,465$2,902Oct 19, 2023Final
Citation 1, item 4b
29 CFR 1910.1053(f)(1) · Silica dust in general industry
Serious$0$0Oct 19, 2023Final
Citation 1, item 4c
29 CFR 1910.1053(f)(3) · Silica dust in general industry
Serious$0$0Oct 19, 2023Final
Citation 1, item 6a
29 CFR 1910.1053(f)(2)(i) · Silica dust in general industry
Serious$4,465$2,902Oct 19, 2023Final
Citation 1, item 6b
29 CFR 1910.1053(j)(1) · Silica dust in general industry
Serious$0$0Oct 19, 2023Final
Citation 1, item 6c
29 CFR 1910.1053(d)(1) · Silica dust in general industry
Serious$4,465$0Oct 19, 2023Final
Citation 1, item 7
29 CFR 1910.1053(i)(1)(i) · Silica dust in general industry
Serious$4,465$2,902Oct 19, 2023Final
Citation 1, item 8
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$4,465$2,902Oct 19, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1053 · Silica dust in general industry

29 CFR 1910.1053(c)

(c) Permissible exposure limit (PEL). The employer shall ensure that no employee is exposed to an airborne concentration of respirable crystalline silica in excess of 50 µg/m 3, calculated as an 8-hour TWA.

29 CFR 1910.1053(d)(1)

(d) Exposure assessment—(1) General. The employer shall assess the exposure of each employee who is or may reasonably be expected to be exposed to respirable crystalline silica at or above the action level in accordance with either the performance option in paragraph (d)(2) or the scheduled monitoring option in paragraph (d)(3) of this section.

29 CFR 1910.1053(f)(1)

(f) Methods of compliance—(1) Engineering and work practice controls. The employer shall use engineering and work practice controls to reduce and maintain employee exposure to respirable crystalline silica to or below the PEL, unless the employer can demonstrate that such controls are not feasible. Wherever such feasible engineering and work practice controls are not sufficient to reduce employee exposure to or below the PEL, the employer shall nonetheless use them to reduce employee exposure to the lowest feasible level and shall supplement them with the use of respiratory protection that complies with the requirements of paragraph (g) of this section.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

Other paint and coating manufacturing employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.