OSHA SearchOSHA records by employer

Superior Interiors, Inc.: OSHA inspections and violations

Boise, Idaho · Finish Carpentry Contractors · NAICS 238350

3inspections
7citation items
$4,575current penalties
Mar 29, 2018last inspection

OSHA has inspected Superior Interiors, Inc. 3 times in Idaho since 2004.

The latest one began on Mar 29, 2018 on a referral, in Eagle.

Those inspections ended with 7 citation items: 7 serious.

Penalties were first proposed at $5,924 and now stand at $4,575, 23% lower after settlements or reviews.

Scaffold training comes up most often in these citations: 3 items under 1926.454.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Superior Interiors, Inc. averages $4,200 (1 cited inspection).

It reported 1 severe injury to OSHA since 2015.

Superior Interiors, Inc.: OSHA citation items per year, 2004 to 2018
Citation items per year, by inspection date.

Idaho · latest 90 days of OSHA records

62employers cited

Get notified the morning OSHA posts each new citation in Idaho: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Idaho

Checking a subcontractor, a client or your own company? Watch Superior Interiors, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343052312 OPENED MAR 29, 2018Closed

Referral · Partial · Safety · 20 employees at the site · Closed Nov 29, 2019

745 E. Riverside Drive, Eagle, ID 83616 · Interior Design Services · OSHA's record · Phone and website on Google Maps

Incident on Mar 28, 2018: Employee falls from scaffold while installing fire tape and

At 10:00 a.m. on March 28, 2018, an employee was installing fire tape while on a scaffold and fell. The employee suffered a fractured back and collarbone when he struck the concrete floor. The employee was hospitalized.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$5,174$4,200Jun 20, 2018Final
Citation 1, item 1b
29 CFR 1926.451(f)(4) · Scaffolds, general requirements
Serious$0$0Jun 20, 2018Final
Citation 1, item 1c
29 CFR 1926.452(w)(2) · Rules for each type of scaffold
Serious$0$0Jun 20, 2018Final
Citation 1, item 1d
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Jun 20, 2018Final
Citation 1, item 1e
29 CFR 1926.454(b) · Scaffold training
Serious$0$0Jun 20, 2018Final

Inspection 309963114 OPENED APR 11, 2006Closed

Referral · Partial · Safety · 12 employees at the site · Closed May 15, 2006

Corner Of N.cormorant & W.fairview, Boise, ID 83642 · Finish Carpentry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$750$375Apr 14, 2006Closed
Citation 1, item 1b
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Apr 14, 2006Closed

Inspection 306441676 OPENED OCT 28, 2004Closed

Unprogrammed related · Partial · Safety · 2 employees at the site · Closed Oct 28, 2004

533 East Riverside Drive Buiding P-27, Boise, ID 83616 · Finish Carpentry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Mar 28, 2018, Eagle: Hospitalization · fractures · shoulder(s) and back

An employee fell through an open shaft while installing drywall, suffering a broken collarbone and back.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

29 CFR 1926.451(f)(4)

(4) Any part of a scaffold damaged or weakened such that its strength is less than that required by paragraph (a) of this section shall be immediately repaired or replaced, braced to meet those provisions, or removed from service until repaired.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.452(w)(2)

(2) Scaffold casters and wheels shall be locked with positive wheel and/or wheel and swivel locks, or equivalent means, to prevent movement of the scaffold while the scaffold is used in a stationary manner.

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.454 · Scaffold training

Other finish carpentry contractors employers in Idaho

Alert subscribers get notified of each newly cited employer in Idaho the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.