OSHA SearchOSHA records by employer

Supreme Construction, LLC: OSHA inspections and violations

Baton Rouge, Louisiana · Masonry Contractors · NAICS 238140

1inspections
8citation items
$9,055current penalties
Apr 13, 2017last inspection

OSHA has inspected Supreme Construction, LLC once in Louisiana.

The inspection began on Apr 13, 2017 as a planned inspection, in Baton Rouge.

That inspection ended with 8 citation items: 6 serious and 2 other-than-serious.

Penalties were first proposed at $18,110 and now stand at $9,055, 50% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 6 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Supreme Construction, LLC averages $9,055 (1 cited inspection).

Supreme Construction, LLC: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Louisiana · latest 90 days of OSHA records

19employers cited

Get notified the morning OSHA posts each new citation in Louisiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Louisiana

Checking a subcontractor, a client or your own company? Watch Supreme Construction, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342246667 OPENED APR 13, 2017Closed

Planned · Partial · Safety · 5 employees at the site · Closed Oct 27, 2017

4460 Lee Ave., Baton Rouge, LA 70809 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$3,622$1,811Aug 23, 2017Final
Citation 1, item 2
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$3,622$1,811Aug 23, 2017Final
Citation 1, item 3
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$3,622$1,811Aug 23, 2017Final
Citation 1, item 4
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$3,622$1,811Aug 23, 2017Final
Citation 1, item 5a
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$3,622$1,811Aug 23, 2017Final
Citation 1, item 5b
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0Aug 23, 2017Final
Citation 2, item 1
29 CFR 1926.454(a) · Scaffold training
Other-than-serious$0$0Aug 23, 2017Final
Citation 2, item 2
29 CFR 1926.454(b) · Scaffold training
Other-than-serious$0$0Aug 23, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.454 · Scaffold training

Other masonry contractors employers in Louisiana

Alert subscribers get notified of each newly cited employer in Louisiana the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.