OSHA SearchOSHA records by employer

Sure DRY Fire & Water Restoration: OSHA inspections and violations

Buffalo, New York · Roofing Contractors · NAICS 238160

1inspections
3citation items
$2,550current penalties
Nov 14, 2018last inspection

OSHA has inspected Sure DRY Fire & Water Restoration once in New York.

The inspection began on Nov 14, 2018 as a planned inspection, in Buffalo.

That inspection ended with 3 citation items: 2 serious and 1 other-than-serious.

Penalties were first proposed at $4,102 and now stand at $2,550, 38% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 2 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Sure DRY Fire & Water Restoration averages $2,550 (1 cited inspection).

Sure DRY Fire & Water Restoration: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

376employers cited

61 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Sure DRY Fire & Water Restoration and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343604898 OPENED NOV 14, 2018Closed

Planned · Partial · Safety · 2 employees at the site · Closed Dec 14, 2020

366 Richmond Avenue, Buffalo, NY 14222 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$1,885$1,000Jan 17, 2019Final
Citation 1, item 2
29 CFR 1926.451(g)(1)(i) · Scaffolds, general requirements
Serious$2,217$1,550Jan 17, 2019Final
Citation 2, item 1
29 CFR 1926.100(a) · Hard hats in construction
Other-than-serious$0$0Jan 17, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(g)(1)(i)

(i) Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold shall be protected by a personal fall arrest system;

Other roofing contractors employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.