Inspection 344982236 OPENED OCT 28, 2020Closed
4108 52nd St Se, Kentwood, MI 49512 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Swoboda Inc. has 8 OSHA inspections on record in Michigan, the first in 2001.
OSHA's last visit started on Oct 28, 2020 after a complaint, in Kentwood.
Across those inspections OSHA issued 43 citation items: 19 serious, 2 willful, 6 repeat and 16 other-than-serious.
OSHA proposed $166,100 in penalties. After settlements and reviews the total is $107,925, down 35%.
Most often, OSHA cited 1910.147, lockout/tagout (8 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Swoboda Inc. averages $4,500 over 1 cited inspection in that time.
Swoboda Inc. also files yearly injury logs with OSHA, summarized below.
Michigan · latest 90 days of OSHA records
656employers cited
5 of them in the same industry
Get notified the morning OSHA posts each new citation in Michigan: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Michigan
Checking a subcontractor, a client or your own company? Watch Swoboda Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company4108 52nd St Se, Kentwood, MI 49512 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
4108 52nd St Se, Kentwood, MI 49512 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 408.13308(1) |
Serious | $3,500 | $1,750 | Jan 26, 2021 | Final |
| Citation 1, item 1b 29 CFR 325.47201(3) |
Serious | $0 | $0 | Jan 26, 2021 | Final |
| Citation 1, item 1c 29 CFR 408.12026 |
Serious | $0 | $0 | Jan 26, 2021 | Final |
| Citation 1, item 2 29 CFR 408.16234(5) |
Serious | $2,000 | $1,000 | Jan 26, 2021 | Final |
| Citation 1, item 3 29 CFR 408.16234(10) |
Serious | $3,500 | $1,750 | Jan 26, 2021 | Final |
4108 52nd St Se, Kentwood, MI 49512 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 | Serious | $4,000 | $2,000 | Jan 15, 2014 | Final |
| Citation 2, item 1 29 CFR 1910.147(c)(4)(i) · Lockout/tagout |
Willful | $63,000 | $44,100 | Jan 15, 2014 | Final |
| Citation 2, item 2 29 CFR 1910.147(c)(7)(ia) · Lockout/tagout |
Willful | $63,000 | $44,100 | Jan 15, 2014 | Final |
4108 52nd St Se, Kentwood, MI 49512 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 | Serious | $1,000 | $400 | Dec 15, 2011 | Closed |
| Citation 1, item 2 | Serious | $750 | $300 | Dec 15, 2011 | Closed |
| Citation 1, item 3a | Serious | $1,000 | $500 | Dec 15, 2011 | Closed |
| Citation 1, item 3b | Serious | $0 | $0 | Dec 15, 2011 | Closed |
| Citation 1, item 4a 29 CFR 1910.303(b)(8)(i) · Electrical equipment, general requirements |
Serious | $1,000 | $400 | Dec 15, 2011 | Closed |
| Citation 1, item 4b 29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods |
Serious | $0 | $0 | Dec 15, 2011 | Closed |
| Citation 2, item 1 | Repeat | $3,750 | $1,500 | Dec 15, 2011 | Closed |
| Citation 2, item 2 29 CFR 1910.147(c)(4)(i) · Lockout/tagout |
Repeat | $8,750 | $4,375 | Dec 15, 2011 | Closed |
| Citation 2, item 3 29 CFR 1910.147(c)(7)(ia) · Lockout/tagout |
Repeat | $3,500 | $1,750 | Dec 15, 2011 | Closed |
| Citation 3, item 1a 29 CFR 1910.106(e)(6)(ii) · Flammable liquids |
Other-than-serious | $0 | $0 | Dec 15, 2011 | Closed |
| Citation 3, item 1b 29 CFR 1910.106(e)(9)(iii) · Flammable liquids |
Other-than-serious | $0 | $0 | Dec 15, 2011 | Closed |
| Citation 4, item 1 | Repeat | $100 | $40 | Dec 15, 2011 | Closed |
4108 52nd St Se, Kentwood, MI 49512 · Industrial Machinery Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.147(c)(4)(i) · Lockout/tagout |
Repeat | $1,750 | $1,050 | Jul 15, 2010 | Closed |
| Citation 2, item 1 | Repeat | $100 | $60 | Jul 15, 2010 | Closed |
4108 52nd St Se, Kentwood, MI 49512 · Industrial Machinery Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
4108 52nd St Se, Kentwood, MI 49512 · Industrial Machinery Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 | Serious | $1,200 | $600 | Oct 15, 2008 | Closed |
| Citation 1, item 2 | Serious | $1,200 | $600 | Oct 15, 2008 | Closed |
| Citation 1, item 3 | Serious | $900 | $450 | Oct 15, 2008 | Closed |
| Citation 1, item 4 | Serious | $900 | $450 | Oct 15, 2008 | Closed |
| Citation 1, item 5a 29 CFR 1910.147(c)(4)(i) · Lockout/tagout |
Serious | $900 | $450 | Oct 15, 2008 | Closed |
| Citation 1, item 5b 29 CFR 1910.147(c)(7)(ia) · Lockout/tagout |
Serious | $0 | $0 | Oct 15, 2008 | Closed |
| Citation 2, item 1 | Other-than-serious | $0 | $0 | Oct 15, 2008 | Closed |
| Citation 2, item 2 | Other-than-serious | $0 | $0 | Oct 15, 2008 | Closed |
| Citation 2, item 3 | Other-than-serious | $0 | $0 | Oct 15, 2008 | Closed |
| Citation 2, item 4 | Other-than-serious | $0 | $0 | Oct 15, 2008 | Closed |
| Citation 2, item 5 | Other-than-serious | $0 | $0 | Oct 15, 2008 | Closed |
| Citation 2, item 6 29 CFR 1910.303(f)(1) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Oct 15, 2008 | Closed |
| Citation 2, item 7 | Other-than-serious | $0 | $0 | Oct 15, 2008 | Closed |
| Citation 2, item 8a 29 CFR 1910.146(c)(1) · Permit-required confined spaces |
Other-than-serious | $0 | $0 | Oct 15, 2008 | Closed |
| Citation 2, item 8b 29 CFR 1910.146(c)(2) · Permit-required confined spaces |
Other-than-serious | $0 | $0 | Oct 15, 2008 | Closed |
| Citation 2, item 8c 29 CFR 1910.146(g)(1) · Permit-required confined spaces |
Other-than-serious | $0 | $0 | Oct 15, 2008 | Closed |
4108 52nd St Se, Kentwood, MI 49512 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 | Serious | $300 | $300 | Apr 4, 2001 | Closed |
| Citation 2, item 1 | Other-than-serious | $0 | $0 | Apr 4, 2001 | Closed |
| Citation 2, item 2 | Other-than-serious | $0 | $0 | Apr 4, 2001 | Closed |
| Citation 2, item 3 29 CFR 1910.147(c)(6)(i) · Lockout/tagout |
Other-than-serious | $0 | $0 | Apr 4, 2001 | Closed |
| Citation 2, item 4 29 CFR 1910.1200(f)(5) · Hazard communication |
Other-than-serious | $0 | $0 | Apr 4, 2001 | Closed |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Kentwood site logged 3 recordable injuries or illnesses among about 102 workers: 3.3 per 100 full-time workers, against a median of 2.7 for its industry.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| Swoboda, Inc. Kentwood · 2025 | 102 | 3 | 0 | 3.3 | 2.7 |
| Swoboda Kentwood · 2019 | 104 | 5 | 0 | 6.6 | 2.7 |
Included with any plan: 4 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
See plansCurrent text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.106(e)(6)(ii)
(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.
29 CFR 1910.106(e)(9)(iii)
(iii) Waste and residue. Combustible waste material and residues in a building or unit operating area shall be kept to a minimum, stored in covered metal receptacles and disposed of daily.
29 CFR 1910.1200(f)(5)
(f) Any organic peroxide which, in laboratory testing, neither detonates in the cavitated state nor deflagrates at all and shows only a low or no effect when heated under confinement as well as low or no explosive power shall be defined as organic peroxide TYPE F;
Alert subscribers get notified of each newly cited employer in Michigan the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.