OSHA SearchOSHA records by employer

Sydnor Hydro Inc.: OSHA inspections and violations

Lancaster, Virginia · Water and Sewer Line and Related Structures Construction · NAICS 237110

5inspections
12citation items
$7,847current penalties
Nov 13, 2018last inspection

Since 2002, OSHA inspectors have visited Sydnor Hydro Inc. in Virginia 5 times.

The most recent inspection opened on Nov 13, 2018 on a referral, in New Kent.

In all, OSHA issued 12 citation items: 7 serious and 5 other-than-serious.

The proposed penalties came to $11,560; today they stand at $7,847, 32% less.

The rule cited most here is 1926.651 (excavations), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Sydnor Hydro Inc. averages $6,377 across 1 cited inspection.

Sydnor Hydro Inc.: OSHA citation items per year, 2002 to 2018
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

249employers cited

6 of them in the same industry

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Sydnor Hydro Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343597654 OPENED NOV 13, 2018Closed

Referral · Partial · Safety · 50 employees at the site · Closed Jan 22, 2019

7324 Vinyards Pkwy, New Kent, VA 23124 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Incident on Nov 2, 2018: Employee, struck by pipe, sustains spine and finger fracture

At 10:30 a.m. on December 2, 2018, Employee #1, employed by a pipeline construction company, was doing repair work at a water/sewer treatment plant. He was cleaning leaves from the intake screen of a 3-inch mud pump pipe when excessive pressure caused the pipe to disconnect from the gooseneck and strike the employee. Employee #1 was transported to the hospital, admitted, and treated for a spinal fracture and a fractured finger.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 16VAC25-60.130
Serious$4,110$2,877Dec 18, 2018Final
Citation 2, item 1
29 CFR 40.1-51.1.D
Other-than-serious$5,000$3,500Dec 18, 2018Final
Citation 2, item 2
29 CFR 1926.350(a)(10) · Gas welding and cutting
Other-than-serious$0$0Dec 18, 2018Final

Inspection 342332970 OPENED MAY 16, 2017Closed

Planned · No inspection · Safety · Closed May 16, 2017

Central Accomack Industrial Airport Park, Melfa, VA 23410 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 317024438 OPENED MAY 21, 2013Closed

Planned · Complete · Safety · 3 employees at the site · Closed Jul 15, 2013

Town Well, Adj. To China Inn Restaurant, Rt. 360, Warsaw, VA 22572 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 316169895 OPENED OCT 21, 2011Closed

Unprogrammed other · Complete · Safety · 100 employees at the site · Closed Dec 9, 2011

1802 D S. Church Street, Smithfield, VA 23430 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Other-than-serious$0$0Nov 10, 2011Closed
Citation 1, item 2
29 CFR 1926.150(c)(1)(viii) · Fire protection
Other-than-serious$0$0Nov 10, 2011Closed

Inspection 304779234 OPENED MAY 9, 2002Closed

Planned · Complete · Safety · 4 employees at the site · Closed Jul 30, 2002

Lancaster Court House, Rt. 3, Lancaster, VA 22503 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.50(c) · Medical services and first aid
Serious$700$420Jun 18, 2002Closed
Citation 1, item 2
29 CFR 1926.100(a) · Hard hats in construction
Serious$525$315Jun 18, 2002Closed
Citation 1, item 3
29 CFR 1926.152(a)(1) · Flammable liquids
Serious$525$315Jun 18, 2002Closed
Citation 1, item 4a
29 CFR 1926.651(c)(2) · Excavations
Serious$700$420Jun 18, 2002Closed
Citation 1, item 4b
29 CFR 1926.651(j)(2) · Excavations
Serious$0$0Jun 18, 2002Closed
Citation 1, item 4c
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$0$0Jun 18, 2002Closed
Citation 2, item 1 Other-than-serious$0$0Jun 18, 2002Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.150 · Fire protection

29 CFR 1926.152 · Flammable liquids

29 CFR 1926.350 · Gas welding and cutting

29 CFR 1926.50 · Medical services and first aid

29 CFR 1926.51 · Sanitation

29 CFR 1926.651 · Excavations

Other water and sewer line and related structures construction employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.