OSHA SearchOSHA records by employer

Szalay Masonry, Inc.: OSHA inspections and violations

Hudson, Wisconsin · Masonry Contractors · NAICS 238140

1inspections
5citation items
$3,400current penalties
Apr 17, 2015last inspection

Szalay Masonry, Inc. has one OSHA inspection on record in Wisconsin.

OSHA opened it on Apr 17, 2015 after a complaint, in Hudson.

From that inspection OSHA issued 5 citation items: 4 serious and 1 other-than-serious.

OSHA proposed $6,800 in penalties. After settlements and reviews the total is $3,400, down 50%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Szalay Masonry, Inc. averages $3,400 over 1 cited inspection in that time.

Szalay Masonry, Inc.: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Wisconsin · latest 90 days of OSHA records

223employers cited

Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wisconsin

Checking a subcontractor, a client or your own company? Watch Szalay Masonry, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340565696 OPENED APR 17, 2015Closed

Complaint · Partial · Safety · 8 employees at the site · Closed Aug 24, 2016

Badger Drive & Gateway Blvd., Hudson, WI 54016 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$1,600$800Aug 12, 2015Final
Citation 1, item 2
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$2,400$1,200Aug 12, 2015Final
Citation 1, item 3
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$1,200$600Aug 12, 2015Final
Citation 1, item 4
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$1,600$800Aug 12, 2015Final
Citation 2, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Other-than-serious$0$0Aug 12, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

Other masonry contractors employers in Wisconsin

Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.