Inspection 341300366 OPENED MAR 1, 2016Closed
3 West Boardway, Lovettsville, VA 20180 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
T & a Construction has 3 OSHA inspections on record in Virginia, the first in 2005.
OSHA's last visit started on Mar 1, 2016, in Lovettsville.
Across those inspections OSHA issued 3 citation items: 3 serious.
OSHA proposed $1,355 in penalties. After settlements and reviews the total is $1,061, down 22%.
For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. T & a Construction averages $686 over 1 cited inspection in that time.
Virginia · latest 90 days of OSHA records
249employers cited
2 of them in the same industry
Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Virginia
Checking a subcontractor, a client or your own company? Watch T & a Construction and get notified the morning OSHA posts a new citation for it.
Watch this company3 West Boardway, Lovettsville, VA 20180 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
22505 Landmark Court, Ashburn, VA 20147 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites |
Serious | $980 | $686 | Sep 22, 2015 | Final |
| Citation 1, item 1b 29 CFR 1926.405(g)(2)(iv) · Job-site wiring |
Serious | $0 | $0 | Sep 22, 2015 | Final |
42010 Village Center Dr., Aldie, VA 20105 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(10) · Fall protection in construction |
Serious | $375 | $375 | Jul 8, 2005 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.404(b)(1)(ii)
(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.
29 CFR 1926.405(g)(2)(iv)
(iv) Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.
29 CFR 1926.501(b)(10)
(10) Roofing work on Low-slope roofs. Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted.
Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.