OSHA SearchOSHA records by employer

T&M Crane Rentals, Inc.: OSHA inspections and violations

Reisterstown, Maryland · All Other Specialty Trade Contractors · NAICS 238990

4inspections
10citation items
$1,125current penalties
Dec 6, 2019last inspection

T&M Crane Rentals, Inc. has 4 OSHA inspections on record in Maryland, the first in 2016.

OSHA's last visit started on Dec 6, 2019 as a planned inspection, in Annapolis.

Across those inspections OSHA issued 10 citation items: 1 serious and 9 other-than-serious.

OSHA proposed $1,125 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.1412, inspections (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. T&M Crane Rentals, Inc. averages $562 over 2 cited inspections in that time.

T&M Crane Rentals, Inc.: OSHA citation items per year, 2016 to 2019
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

178employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch T&M Crane Rentals, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344498126 OPENED DEC 6, 2019Closed

Planned · Complete · Safety · 1 employee at the site · Closed Dec 10, 2019

West End Row 285 West Street, Annapolis, MD 21401 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343908737 OPENED APR 2, 2019Closed

Planned · Complete · Safety · 1 employee at the site · Closed Jul 3, 2019

5994 Whelan Lane Lots 184 - 191, Frederick, MD 21703 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1433(d)(4)(ii) · Design, construction and testing
Serious$375$375Jun 4, 2019Final
Citation 2, item 1
29 CFR 1926.1412(d)(1) · Inspections
Other-than-serious$0$0Jun 4, 2019Final
Citation 2, item 2
29 CFR 1926.1412(e)(1) · Inspections
Other-than-serious$0$0Jun 4, 2019Final
Citation 2, item 3
29 CFR 1926.1412(e)(3) · Inspections
Other-than-serious$0$0Jun 4, 2019Final
Citation 2, item 4
29 CFR 1926.1413(a)(1) · Wire rope—inspection
Other-than-serious$0$0Jun 4, 2019Final
Citation 2, item 5
29 CFR 1926.1413(b)(1) · Wire rope—inspection
Other-than-serious$0$0Jun 4, 2019Final
Citation 2, item 6
29 CFR 1926.1413(b)(4) · Wire rope—inspection
Other-than-serious$0$0Jun 4, 2019Final

Inspection 342141827 OPENED MAR 1, 2017Closed

Planned · Complete · Safety · 1 employee at the site · Closed Jun 15, 2017

3225 Crain Highway, Saint Charles, MD 20603 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 09.12.26.05D(1)
Other-than-serious$750$750Apr 11, 2017Final
Citation 2, item 1
29 CFR 1926.150(a)(4) · Fire protection
Other-than-serious$0$0Apr 11, 2017Final
Citation 2, item 2
29 CFR 1926.1412(d)(1) · Inspections
Other-than-serious$0$0Apr 11, 2017Final

Inspection 341173300 OPENED JAN 15, 2016Closed

Unprogrammed related · Partial · Safety · 1 employee at the site · Closed Jan 15, 2016

2417 Tufton Springs Lane, Reisterstown, MD 21136 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1412 · Inspections

29 CFR 1926.1412(d)(1)

(d) Each shift. (1) A competent person must begin a visual inspection prior to each shift the equipment will be used, which must be completed before or during that shift. The inspection must consist of observation for apparent deficiencies. Taking apart equipment components and booming down is not required as part of this inspection unless the results of the visual inspection or trial operation indicate that further investigation necessitating taking apart equipment components or booming down is needed. Determinations made in conducting the inspection must be reassessed in light of observations made during operation. At a minimum the inspection must include all of the following:

29 CFR 1926.1412(e)(1)

(e) Monthly. (1) Each month the equipment is in service it must be inspected in accordance with paragraph (d) of this section (each shift).

29 CFR 1926.1413 · Wire rope—inspection

29 CFR 1926.1413(a)(1)

(a) Shift inspection. (1) A competent person must begin a visual inspection prior to each shift the equipment is used, which must be completed before or during that shift. The inspection must consist of observation of wire ropes (running and standing) that are likely to be in use during the shift for apparent deficiencies, including those listed in paragraph (a)(2) of this section. Untwisting (opening) of wire rope or booming down is not required as part of this inspection.

29 CFR 1926.1433 · Design, construction and testing

29 CFR 1926.150 · Fire protection

Other all other specialty trade contractors employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.