OSHA SearchOSHA records by employer

T & P Contracting, Inc.: OSHA inspections and violations

Charlestown, Massachusetts · Poured Concrete Foundation and Structure Contractors · NAICS 238110

6inspections
20citation items
$52,243current penalties
Mar 9, 2023last inspection

OSHA has inspected T & P Contracting, Inc. 6 times in Massachusetts since 2000.

The latest one began on Mar 9, 2023 on a referral, in Boston.

Those inspections ended with 20 citation items: 16 serious, 3 repeat and 1 other-than-serious.

Penalties were first proposed at $57,961 and now stand at $52,243, 10% lower after settlements or reviews.

Excavations comes up most often in these citations: 5 items under 1926.651.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and T & P Contracting, Inc. averages $12,134 (2 cited inspections).

T & P Contracting, Inc.: OSHA citation items per year, 2000 to 2023
Citation items per year, by inspection date.

Massachusetts · latest 90 days of OSHA records

260employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Massachusetts: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Massachusetts

Checking a subcontractor, a client or your own company? Watch T & P Contracting, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346571490 OPENED MAR 9, 2023Closed

Referral · Partial · Safety · 6 employees at the site · Closed Aug 14, 2025

500 Talbot Ave., Boston, MA 02124 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$4,219$4,219Jul 14, 2023Final
Citation 1, item 2
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$4,219$4,219Jul 14, 2023Final
Citation 1, item 3
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$4,219$4,219Jul 14, 2023Final
Citation 1, item 4
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$4,219$4,219Jul 14, 2023Final

Inspection 340677467 OPENED APR 6, 2015Closed

Unprogrammed related · Partial · Safety · 10 employees at the site · Closed Feb 17, 2017

42-42r Olny Street, Dorchester, MA 02122 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(c)(2) · Excavations
Repeat$4,400$3,080Jun 11, 2015Final
Citation 1, item 2
29 CFR 1926.652(a)(1) · Trench protection
Repeat$6,160$4,312Jun 11, 2015Final

Inspection 316372101 OPENED FEB 24, 2012Closed

Unprogrammed other · Complete · Safety · 3 employees at the site · Closed Jun 5, 2014

44-54 Rutherford Avenue, Charlestown, MA 02129 · Other Foundation, Structure, and Building Exterior Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(c)(2) · Excavations
Serious$3,000$3,000May 3, 2012Closed
Citation 1, item 2
29 CFR 1926.651(j)(2) · Excavations
Serious$4,200$4,200May 3, 2012Closed
Citation 1, item 3
29 CFR 1926.652(a)(1) · Trench protection
Serious$4,200$4,200May 3, 2012Closed
Citation 1, item 4
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$4,200$4,200May 3, 2012Closed
Citation 2, item 1
29 CFR 1926.651(k)(1) · Excavations
Repeat$8,400$8,400May 3, 2012Closed

Inspection 315136945 OPENED DEC 23, 2010Closed

Unprogrammed related · Complete · Safety · 8 employees at the site · Closed Feb 24, 2011

75 Park Street, North Andover, MA 01845 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$3,000$2,100Jan 25, 2011Closed

Inspection 312102569 OPENED DEC 10, 2008Closed

Referral · Partial · Safety · 3 employees at the site · Closed Apr 7, 2009

B Street And West Fourth, South Boston, MA 02127 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.21(b)(2) · Construction safety training
Serious$600$300Jan 15, 2009Closed
Citation 1, item 2
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$750$375Jan 15, 2009Closed
Citation 1, item 3
29 CFR 1926.451(g)(4)(iv) · Scaffolds, general requirements
Serious$750$375Jan 15, 2009Closed
Citation 1, item 4
29 CFR 1926.451(h)(2)(v) · Scaffolds, general requirements
Serious$600$300Jan 15, 2009Closed
Citation 1, item 5
29 CFR 1926.651(k)(1) · Excavations
Serious$600$300Jan 15, 2009Closed

Inspection 302922638 OPENED JUL 24, 2000Closed

Unprogrammed related · Partial · Safety · 4 employees at the site · Closed Sep 21, 2000

399 & 401 Bunker Hill Street, Charlestown, MA 02129 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$225$225Jul 28, 2000Closed
Citation 1, item 1b
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$0$0Jul 28, 2000Closed
Citation 2, item 1
29 CFR 1926.100(a) · Hard hats in construction
Other-than-serious$0$0Jul 28, 2000Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.21 · Construction safety training

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

29 CFR 1926.651 · Excavations

29 CFR 1926.652 · Trench protection

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

Other poured concrete foundation and structure contractors employers in Massachusetts

Alert subscribers get notified of each newly cited employer in Massachusetts the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.