Inspection 343348363 OPENED AUG 1, 2018Closed
20200 Hwy 12, Weston, CO 81091 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps
Incident on Jul 31, 2018: Two employees experience carbon monoxide poisoning while usi
At 8:30 a.m. on July 31, 2018, two employees were conducting concrete floor cutting operations using a propane/gas powered concrete saw (Diamond Products Model Number CC2500, Serial Number 147801) in a 14 foot long by 8 foot wide by 8 foot high room. The employees had been working in the poorly/unventilated room for approximately 160 minutes when they were overwhelmed by the carbon monoxide contained in the saws exhaust. Both employees were hospitalized with characteristic symptoms of carbon monoxide poisoning (headaches, severe weakness, chest pain, and shortness of breath).
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.55(a) · Gases, vapors, fumes, dusts, and mists |
Other-than-serious | $5,174 | $5,174 | Nov 19, 2018 | Final |
| Citation 1, item 1b 29 CFR 1926.55(b) · Gases, vapors, fumes, dusts, and mists |
Other-than-serious | $0 | $0 | Nov 19, 2018 | Final |