OSHA SearchOSHA records by employer

T&W Stamping: OSHA inspections and violations

Alliance, Ohio · Forging and Stamping · NAICS 332116

6inspections
24citation items
$17,605current penalties
Feb 23, 2024last inspection

OSHA has inspected T&W Stamping 6 times in Ohio since 2002.

The latest one began on Feb 23, 2024 as a planned inspection, in Youngstown.

Those inspections ended with 24 citation items: 20 serious, 1 repeat and 3 other-than-serious.

Penalties were first proposed at $30,267 and now stand at $17,605, 42% lower after settlements or reviews.

Mechanical power presses comes up most often in these citations: 8 items under 1910.217.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and T&W Stamping averages $3,952 (2 cited inspections).

T&W Stamping: OSHA citation items per year, 2002 to 2024
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

263employers cited

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch T&W Stamping and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347302069 OPENED FEB 23, 2024Closed

Planned · Partial · Safety · 34 employees at the site · Closed Jul 3, 2024

207 North 4 Mile Run Road, Youngstown, OH 44515 · Machine Shops · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.255(b)(4) · Resistance welding
Serious$6,453$4,517May 13, 2024Final

Inspection 347303620 OPENED FEB 23, 2024Closed

Complaint · Partial · Health · 28 employees at the site · Closed Jul 3, 2024

207 North 4 Mile Run Road, Youngstown, OH 44515 · Machine Shops · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$4,839$3,387May 13, 2024Final
Citation 1, item 1b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0May 13, 2024Final
Citation 1, item 1c
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0May 13, 2024Final

Inspection 344323431 OPENED SEP 20, 2019Closed

Complaint · Partial · Health · 100 employees at the site · Closed Oct 15, 2019

930 West Ely St., Alliance, OH 44601 · Forging and Stamping · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 313212326 OPENED MAY 6, 2009Closed

Planned · No inspection · Safety · Closed May 6, 2009

930 West Ely St., Alliance, OH 44601 · Forging and Stamping · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 308255074 OPENED OCT 1, 2004Closed

Complaint · Partial · Safety · 70 employees at the site · Closed Aug 19, 2005

930 West Ely St., Alliance, OH 44601 · Forging and Stamping · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.157(g)(2) · Portable fire extinguishers
Serious$1,200$798Oct 25, 2004Closed
Citation 1, item 2a
29 CFR 1910.213(h)(1) · Woodworking machinery
Serious$2,000$1,000Oct 25, 2004Closed
Citation 1, item 2b
29 CFR 1910.213(h)(4) · Woodworking machinery
Serious$0$0Oct 25, 2004Closed
Citation 1, item 3a
29 CFR 1910.217(b)(7)(ix) · Mechanical power presses
Serious$1,600$800Oct 25, 2004Closed
Citation 1, item 3b
29 CFR 1910.217(b)(7)(xv) · Mechanical power presses
Serious$0$0Oct 25, 2004Closed
Citation 1, item 3c
29 CFR 1910.217(b)(7)(viii) · Mechanical power presses
Serious$0$0Oct 25, 2004Closed
Citation 1, item 4
29 CFR 1910.217(c)(2)(ia) · Mechanical power presses
Serious$2,000$1,000Oct 25, 2004Closed
Citation 1, item 5
29 CFR 1910.217(c)(3)(iia) · Mechanical power presses
Serious$4,000$2,000Oct 25, 2004Closed
Citation 1, item 6
29 CFR 1910.217(c)(3)(viid) · Mechanical power presses
Serious$4,000$2,000Oct 25, 2004Closed
Citation 1, item 7a
29 CFR 1910.217(e)(1)(i) · Mechanical power presses
Other-than-serious$1,600$0Oct 25, 2004Closed
Citation 1, item 7b
29 CFR 1910.217(e)(1)(ii) · Mechanical power presses
Serious$0$0Oct 25, 2004Closed
Citation 2, item 1
29 CFR 1910.101(b) · Compressed gases (general requirements)
Repeat$200$200Oct 25, 2004Closed
Citation 2, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Serious$800$800Oct 25, 2004Closed
Citation 3, item 1
29 CFR 1910.147(c)(4)(iic) · Lockout/tagout
Other-than-serious$0$0Oct 25, 2004Closed
Citation 3, item 2
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Other-than-serious$0$0Oct 25, 2004Closed

Inspection 305324907 OPENED JUN 11, 2002Closed

Planned · Partial · Safety · 50 employees at the site · Closed Aug 9, 2002

930 West Ely St., Alliance, OH 44601 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.101(b) · Compressed gases (general requirements)
Serious$525$368Jun 20, 2002Closed
Citation 1, item 1b
29 CFR 1910.253(b)(2)(iv) · Gas welding and cutting
Serious$0$0Jun 20, 2002Closed
Citation 1, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Serious$525$368Jun 20, 2002Closed
Citation 1, item 3a
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$525$368Jun 20, 2002Closed
Citation 1, item 3b
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Jun 20, 2002Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.101 · Compressed gases (general requirements)

29 CFR 1910.101(b)

(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)(i)

(i) A list of the hazardous chemicals known to be present using a product identifier that is referenced on the appropriate safety data sheet (the list may be compiled for the workplace as a whole or for individual work areas); and,

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.217 · Mechanical power presses

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.255 · Resistance welding

Other forging and stamping employers in Ohio

Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.