T Fuller Construction Inc: OSHA inspections and violations

Waterloo, Illinois · Roofing Contractors · NAICS 238160

2inspections
6citation items
$7,000current penalties
Apr 2, 2015last inspection

Since 2015, OSHA inspectors have visited T Fuller Construction Inc in Illinois 2 times.

The most recent inspection opened on Apr 2, 2015 after a complaint, in Waterloo.

In all, OSHA issued 6 citation items: 6 serious.

The proposed penalties came to $9,200; today they stand at $7,000, 24% less.

The rule cited most here is 1926.1053 (ladders in construction), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. T Fuller Construction Inc averages $7,000 across 1 cited inspection.

T Fuller Construction Inc: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Illinois · latest 90 days of OSHA records

423employers cited

154 of them in the same industry

Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Illinois

Checking a subcontractor, a client or your own company? Watch T Fuller Construction Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340508217 OPENED APR 2, 2015Closed

Complaint · No inspection · Safety · 1 employee at the site · Closed May 21, 2015

340 Sandwood, Waterloo, IL 62298 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340480490 OPENED MAR 23, 2015Closed

Complaint · Partial · Safety · 5 employees at the site · Closed Oct 26, 2015

622 N Market Street, Waterloo, IL 62298 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$1,200$913May 13, 2015Final
Citation 1, item 2
29 CFR 1926.405(a)(2)(ii)(j) · Job-site wiring
Serious$1,200$913May 13, 2015Final
Citation 1, item 3
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$2,000$1,522May 13, 2015Final
Citation 1, item 4
29 CFR 1926.503(a)(2)(iii) · Fall protection training in construction
Serious$0$0May 13, 2015Final
Citation 1, item 5
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$2,000$1,522May 13, 2015Final
Citation 1, item 6
29 CFR 1926.1053(b)(16) · Ladders in construction
Serious$2,800$2,130May 13, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(16)

(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other roofing contractors employers in Illinois

Alert subscribers get notified of each newly cited employer in Illinois the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.