Inspection 344640909 OPENED FEB 20, 2020Closed
240 And 244 Brentwood Drive N, Lake Placid, FL 33852 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Since 2015, OSHA inspectors have visited T.M. Scott Inc. in Florida 2 times.
The most recent inspection opened on Feb 20, 2020 after a complaint, in Lake Placid.
In all, OSHA issued 3 citation items: 2 serious and 1 other-than-serious.
The proposed penalties came to $4,000; today they stand at $2,400, 40% less.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. T.M. Scott Inc. averages $2,400 across 1 cited inspection.
Florida · latest 90 days of OSHA records
326employers cited
70 of them in the same industry
Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Florida
Checking a subcontractor, a client or your own company? Watch T.M. Scott Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company240 And 244 Brentwood Drive N, Lake Placid, FL 33852 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
First Presbyterian Church 319 Poinsettia Ave, Sebring, FL 33870 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(10) · Fall protection in construction |
Serious | $2,000 | $1,200 | Feb 2, 2016 | Final |
| Citation 1, item 2 29 CFR 1926.1053(b)(1) · Ladders in construction |
Serious | $2,000 | $1,200 | Feb 2, 2016 | Final |
| Citation 2, item 1 29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites |
Other-than-serious | $0 | $0 | Feb 2, 2016 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.1053(b)(1)
(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.
29 CFR 1926.404(b)(1)(i)
(b) Branch circuits—(1) Ground-fault protection—(i) General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.
29 CFR 1926.501(b)(10)
(10) Roofing work on Low-slope roofs. Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted.
Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.