OSHA SearchOSHA records by employer

Talanca Masonry, LLC: OSHA inspections and violations

Jessup, Pennsylvania · Masonry Contractors · NAICS 238140

1inspections
5citation items
$9,000current penalties
May 17, 2018last inspection

Talanca Masonry, LLC has one OSHA inspection on record in Pennsylvania.

OSHA opened it on May 17, 2018 as a planned inspection, in Jessup.

From that inspection OSHA issued 5 citation items: 2 serious and 3 other-than-serious.

OSHA proposed $15,522 in penalties. After settlements and reviews the total is $9,000, down 42%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Talanca Masonry, LLC averages $9,000 over 1 cited inspection in that time.

Talanca Masonry, LLC: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

277employers cited

6 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Talanca Masonry, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343167151 OPENED MAY 17, 2018Closed

Planned · Complete · Safety · 6 employees at the site · Closed Jun 26, 2018

220 Valley View Drive, Jessup, PA 18434 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(g)(1)(vi) · Scaffolds, general requirements
Serious$5,174$4,000Jun 12, 2018Final
Citation 1, item 1b
29 CFR 1926.451(g)(4)(vii) · Scaffolds, general requirements
Other-than-serious$0$0Jun 12, 2018Final
Citation 1, item 2
29 CFR 1926.451(c)(2)(ii) · Scaffolds, general requirements
Serious$3,696$3,000Jun 12, 2018Final
Citation 1, item 3
29 CFR 1926.451(b)(8) · Scaffolds, general requirements
Other-than-serious$2,956$1,000Jun 12, 2018Final
Citation 1, item 4
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Other-than-serious$3,696$1,000Jun 12, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(8)

(8) At all points of a scaffold where the platform changes direction, such as turning a corner, any platform that rests on a bearer at an angle other than a right angle shall be laid first, and platforms which rest at right angles over the same bearer shall be laid second, on top of the first platform.

29 CFR 1926.451(c)(2)(ii)

(ii) Unstable objects shall not be used to support scaffolds or platform units.

29 CFR 1926.451(g)(1)(vi)

(vi) Each employee performing overhand bricklaying operations from a supported scaffold shall be protected from falling from all open sides and ends of the scaffold (except at the side next to the wall being laid) by the use of a personal fall arrest system or guardrail system (with minimum 200 pound toprail capacity).

29 CFR 1926.452 · Rules for each type of scaffold

Other masonry contractors employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.