OSHA SearchOSHA records by employer

Taylor Northwest LLC: OSHA inspections and violations

Bend, Oregon · Water Supply and Irrigation Systems · NAICS 221310

15inspections
4citation items
$390current penalties
Sep 12, 2022last inspection

Taylor Northwest LLC has 15 OSHA inspections on record in Oregon, the first in 2009.

OSHA's last visit started on Sep 12, 2022 as a planned inspection, in Prineville.

Across those inspections OSHA issued 4 citation items: 3 serious and 1 other-than-serious.

OSHA proposed $4,590 in penalties. After settlements and reviews the total is $390, down 92%.

Most often, OSHA cited 1926.652, trench protection (2 items).

For context, across all utility employers the median penalty per cited inspection since 2015 is $0. Taylor Northwest LLC averages $120 over 2 cited inspections in that time.

Taylor Northwest LLC: OSHA citation items per year, 2009 to 2022
Citation items per year, by inspection date.

Oregon · latest 90 days of OSHA records

388employers cited

Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oregon

Checking a subcontractor, a client or your own company? Watch Taylor Northwest LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346231533 OPENED SEP 12, 2022Closed

Planned · Partial · Safety · 161 employees at the site · Closed Mar 1, 2023

Nw 3rd St & Nw Deer St, Prineville, OR 97754 · Water Supply and Irrigation Systems · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.652(a)(1) · Trench protection
Serious$240$240Oct 20, 2022Final

Inspection 344331285 OPENED AUG 29, 2019Closed

Complaint · Partial · Safety · 135 employees at the site · Closed Jul 12, 2023

972 S Main St, Prineville, OR 97754 · Water Supply and Irrigation Systems · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342698016 OPENED OCT 12, 2017Closed

Complaint · Partial · Safety · 123 employees at the site · Closed Oct 13, 2017

2500 Medical Center Dr, Bend, OR 97701 · Water Supply and Irrigation Systems · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340637628 OPENED FEB 19, 2015Closed

Accident · Partial · Safety · 10 employees at the site · Closed Oct 18, 2016

61151 15th St, Bend, OR 97702 · Water Supply and Irrigation Systems · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(j)(1) · Excavations
Serious$4,200$0May 4, 2015Final

Inspection 340546886 OPENED FEB 10, 2015Closed

Planned · Complete · Safety · 85 employees at the site · Closed Feb 10, 2015

1416 Sw Cascade Ave, Redmond, OR 97756 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 339455107 OPENED NOV 1, 2013Closed

Planned · Complete · Safety · 80 employees at the site · Closed Jan 30, 2014

Hwy 26 Mp84.9, Warm Springs, OR 97761 · Water Supply and Irrigation Systems · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 315930842 OPENED APR 8, 2013Closed

Accident · Partial · Safety · 73 employees at the site · Closed Aug 2, 2013

Murphy Rd And Brosterhous, Bend, OR 97701 · Water Supply and Irrigation Systems · OSHA's record · Phone and website on Google Maps

Incident on Apr 4, 2013: Driver injured when he backs truck into 25 ft. deep hole

On April 4, 2013, Employee #1, a 40-year-old male dump truck driver with Taylor Northwest Llc, was backing up to an approximately 25 ft. deep hole. It was repor ted that there was poor communication between Employee #1 and the spotter, Emplo yee #1 backed the dump truck into the hole. Employee #1 was injured but did not require hospitalization in the event.

No citations from this inspection.

Inspection 315929778 OPENED JAN 15, 2013Closed

Planned · Complete · Safety · 100 employees at the site · Closed Jan 15, 2013

19800 Touchmark Way, Bend, OR 97702 · Water Supply and Irrigation Systems · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

7 older inspections

Inspection 315927608 OPENED JUL 24, 2012Closed

Planned · Complete · Safety · 49 employees at the site · Closed Jan 4, 2013

20120 Pinebrook Blvd, Bend, OR 97702 · Water Supply and Irrigation Systems · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.652(a)(1) · Trench protection
Serious$150$150Sep 7, 2012Closed

Inspection 315925594 OPENED MAR 22, 2012Closed

Planned · Partial · Safety · 40 employees at the site · Closed Mar 22, 2012

1600 Sw Baldwin Rd, Prineville, OR 97754 · Water Supply and Irrigation Systems · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 315923763 OPENED NOV 16, 2011Closed

Planned · Partial · Safety · 49 employees at the site · Closed Nov 16, 2011

Yew Ave And S Canal Ave, Redmond, OR 97756 · Water Supply and Irrigation Systems · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 315922823 OPENED OCT 13, 2011Closed

Planned · Complete · Safety · 9 employees at the site · Closed Oct 13, 2011

S Main St Improvements, Milton-freewater, OR 97862 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 314520552 OPENED SEP 27, 2010Closed

Planned · Partial · Safety · 5 employees at the site · Closed Sep 27, 2010

63465 Highway 97, Bend, OR 97701 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 313463614 OPENED FEB 9, 2010Closed

Planned · Partial · Safety · 28 employees at the site · Closed Feb 9, 2010

716 Oak St, Sisters, OR 97759 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 312264997 OPENED FEB 9, 2009Closed

Planned · Complete · Safety · 26 employees at the site · Closed Jun 29, 2009

61050 Se 27th St, Bend, OR 97702 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.150(c)(1)(viii) · Fire protection
Other-than-serious$0$0Mar 4, 2009Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(c)(1)(viii)

(viii) Portable fire extinguishers shall be inspected periodically and maintained in accordance with Maintenance and Use of Portable Fire Extinguishers, NFPA No. 10A-1970.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(j)(1)

(j) Protection of employees from loose rock or soil. (1) Adequate protection shall be provided to protect employees from loose rock or soil that could pose a hazard by falling or rolling from an excavation face. Such protection shall consist of scaling to remove loose material; installation of protective barricades at intervals as necessary on the face to stop and contain falling material; or other means that provide equivalent protection.

29 CFR 1926.652 · Trench protection

29 CFR 1926.652(a)(1)

(a) Protection of employees in excavations. (1) Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section except when:

Other water supply and irrigation systems employers in Oregon

Alert subscribers get notified of each newly cited employer in Oregon the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.