OSHA SearchOSHA records by employer

Taylor Utilities, Inc.: OSHA inspections and violations

Cheltenham, Maryland · Water and Sewer Line and Related Structures Construction · NAICS 237110

6inspections
6citation items
$1,020current penalties
Oct 16, 2018last inspection

Taylor Utilities, Inc. has 6 OSHA inspections on record in Maryland, the first in 1987.

OSHA's last visit started on Oct 16, 2018 as a planned inspection, in Fort Washington.

Across those inspections OSHA issued 6 citation items: 6 serious.

OSHA proposed $1,420 in penalties. After settlements and reviews the total is $1,020, down 28%.

Most often, OSHA cited 1926.652, trench protection (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Taylor Utilities, Inc. averages $450 over 1 cited inspection in that time.

Taylor Utilities, Inc.: OSHA citation items per year, 1987 to 2018
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

194employers cited

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Taylor Utilities, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343579595 OPENED OCT 16, 2018Closed

Planned · Complete · Safety · 8 employees at the site · Closed Feb 14, 2019

Ridgevale Ave & Scarborough Dr, Fort Washington, MD 20744 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.652(c)(2)(ii) · Trench protection
Serious$450$450Dec 20, 2018Final
Citation 1, item 1b
29 CFR 1926.652(c)(2)(iii) · Trench protection
Serious$0$0Dec 20, 2018Final
Citation 1, item 1c
29 CFR 1926.651(j)(2) · Excavations
Serious$0$0Dec 20, 2018Final
Citation 1, item 1d
29 CFR 1926.651(k)(1) · Excavations
Serious$0$0Dec 20, 2018Final

Inspection 119565331 OPENED APR 29, 1997Closed

Referral · Complete · Safety · 8 employees at the site · Closed Apr 29, 1997

B & A Boulevard, Pasadena, MD 21122 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 127368504 OPENED SEP 30, 1996Closed

Unprogrammed other · Complete · Safety · 20 employees at the site · Closed Sep 30, 1996

9111 Belair Rd., Perry Hall, MD 21236 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 119525228 OPENED MAR 17, 1995Closed

Referral · Partial · Safety · 7 employees at the site · Closed Mar 27, 1995

Oakwood Road And Blossom Lane, Glen Burnie, MD 21061 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 104453394 OPENED AUG 8, 1991Closed

Planned · Complete · Safety · 6 employees at the site · Closed Sep 23, 1991

6812 High Bridge Rd, Bowie, MD 20737 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.652(a)(1) · Trench protection
Serious$630$400Aug 28, 1991Closed

Inspection 18810663 OPENED MAR 9, 1987Closed

Planned · Complete · Safety · 6 employees at the site · Closed Jun 30, 1987

1/10 Mi S. Of Angora Dr. On Frank Tippet Road, Cheltenham, MD 20623 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.652(c) · Trench protection
Serious$340$170Mar 30, 1987Contested

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(j)(2)

(2) Employees shall be protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection shall be provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.

29 CFR 1926.651(k)(1)

(k) Inspections. (1) Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.

29 CFR 1926.652 · Trench protection

29 CFR 1926.652(a)(1)

(a) Protection of employees in excavations. (1) Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section except when:

Other water and sewer line and related structures construction employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.