OSHA SearchOSHA records by employer

TB Masonry LC: OSHA inspections and violations

Garner, Iowa · Masonry Contractors · NAICS 238140

1inspections
3citation items
$158current penalties
Oct 3, 2016last inspection

TB Masonry LC has one OSHA inspection on record in Iowa.

OSHA opened it on Oct 3, 2016, in Garner.

From that inspection OSHA issued 3 citation items: 1 serious and 2 other-than-serious.

OSHA proposed $315 in penalties. After settlements and reviews the total is $158, down 50%.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. TB Masonry LC averages $158 over 1 cited inspection in that time.

TB Masonry LC: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Iowa · latest 90 days of OSHA records

63employers cited

Get notified the morning OSHA posts each new citation in Iowa: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Iowa

Checking a subcontractor, a client or your own company? Watch TB Masonry LC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341819167 OPENED OCT 3, 2016Closed

Unprogrammed other · Complete · Safety · 4 employees at the site · Closed Feb 23, 2017

416 State St, Garner, IA 50438 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.300(b)(2) · Tools—Hand and Power: general requirements
Serious$225$112Nov 29, 2016Final
Citation 2, item 1
29 CFR 1926.405(b)(2) · Job-site wiring
Other-than-serious$0$0Nov 29, 2016Final
Citation 2, item 2
29 CFR 1926.416(e)(1) · Electrical safety in construction
Other-than-serious$90$45Nov 29, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.300 · Tools—Hand and Power: general requirements

29 CFR 1926.300(b)(2)

(2) Belts, gears, shafts, pulleys, sprockets, spindles, drums, fly wheels, chains, or other reciprocating, rotating or moving parts of equipment shall be guarded if such parts are exposed to contact by employees or otherwise create a hazard. Guarding shall meet the requirements as set forth in American National Standards Institute, B15.1-1953 (R1958), Safety Code for Mechanical Power-Transmission Apparatus.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(b)(2)

(2) Covers and canopies. All pull boxes, junction boxes, and fittings shall be provided with covers. If metal covers are used, they shall be grounded. In energized installations each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.416(e)(1)

(e) Cords and cables. (1) Worn or frayed electric cords or cables shall not be used.