TCM Construction, Inc.: OSHA inspections and violations

Syracuse, New York · Roofing Contractors · NAICS 238160

3inspections
5citation items
$8,011current penalties
Aug 26, 2019last inspection

TCM Construction, Inc. has 3 OSHA inspections on record in New York, the first in 1986.

OSHA's last visit started on Aug 26, 2019 on a referral, in Syracuse.

Across those inspections OSHA issued 5 citation items: 4 serious and 1 other-than-serious.

OSHA proposed $12,335 in penalties. After settlements and reviews the total is $8,011, down 35%.

Most often, OSHA cited 1926.501, fall protection in construction (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. TCM Construction, Inc. averages $4,006 over 2 cited inspections in that time.

TCM Construction, Inc.: OSHA citation items per year, 1986 to 2019
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

353employers cited

57 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch TCM Construction, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344259296 OPENED AUG 26, 2019Closed

Referral · Complete · Safety · 7 employees at the site · Closed Apr 10, 2024

394 Coleridge Avenue, Syracuse, NY 13204 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$3,410$3,410Sep 17, 2019Final
Citation 1, item 2a
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$2,273$2,273Sep 17, 2019Final
Citation 1, item 2b
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$0$0Sep 17, 2019Final

Inspection 343457347 OPENED AUG 20, 2018Closed

Unprogrammed other · Complete · Safety · 6 employees at the site · Closed Apr 5, 2023

731 Ostrom Avenue, Syracuse, NY 13201 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Other-than-serious$3,880$0Nov 30, 2018Final
Citation 1, item 2
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$2,772$2,328Nov 30, 2018Final

Inspection 2281269 OPENED MAY 22, 1986Closed

Planned · Complete · Safety · 1 employee at the site · Closed May 23, 1986

North Hills Village Hall-shelter Rock Rd., North Hills, NY 11040 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(4)

(4) Ladders shall be used only for the purpose for which they were designed.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.501 · Fall protection in construction

Other roofing contractors employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.