OSHA SearchOSHA records by employer

Tee Pee Corporation: OSHA inspections and violations

La Junta, Colorado · Commercial and Institutional Building Construction · NAICS 236220

4inspections
14citation items
$13,950current penalties
Apr 27, 2016last inspection

OSHA has inspected Tee Pee Corporation 4 times in Colorado since 2008.

The latest one began on Apr 27, 2016 after a complaint, in Durango.

Those inspections ended with 14 citation items: 1 serious and 13 other-than-serious.

Penalties were first proposed at $17,070 and now stand at $13,950, 18% lower after settlements or reviews.

Fall protection in construction comes up most often in these citations: 3 items under 1926.501.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Tee Pee Corporation averages $2,800 (1 cited inspection).

Tee Pee Corporation: OSHA citation items per year, 2008 to 2016
Citation items per year, by inspection date.

Colorado · latest 90 days of OSHA records

130employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Colorado

Checking a subcontractor, a client or your own company? Watch Tee Pee Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341440642 OPENED APR 27, 2016Closed

Complaint · Partial · Safety · 4 employees at the site · Closed Jul 1, 2016

21719 Hwy 160 W, Durango, CO 81301 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Other-than-serious$2,800$2,800May 10, 2016Final
Citation 1, item 1b
29 CFR 1926.451(g)(1)(v) · Scaffolds, general requirements
Other-than-serious$0$0May 10, 2016Final

Inspection 339778482 OPENED MAY 19, 2014Closed

Planned · Partial · Safety · 2 employees at the site · Closed Sep 2, 2014

610 Genoa, Castle Rock, CO 80109 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(4)(ii) · Fall protection in construction
Other-than-serious$2,200$1,800Jul 15, 2014Final
Citation 1, item 2
29 CFR 1926.1052(c)(1)(i) · Stairways in construction
Other-than-serious$1,320$1,000Jul 15, 2014Final

Inspection 312141336 OPENED JUN 1, 2009Closed

Planned · Partial · Safety · 1 employee at the site · Closed Oct 8, 2010

1302 N. Main St., Lamar, CO 81052 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.150(c)(1)(i) · Fire protection
Other-than-serious$625$525Jun 26, 2009Closed
Citation 1, item 2a
29 CFR 1926.453(a)(1) · Aerial lifts
Other-than-serious$625$525Jun 26, 2009Closed
Citation 1, item 4
29 CFR 1926.601(b)(9) · Motor vehicles
Other-than-serious$625$425Jun 26, 2009Closed
Citation 1, item 5
29 CFR 1926.501(b)(13) · Fall protection in construction
Other-than-serious$0$1,500Jun 26, 2009Closed
Citation 2, item 1
29 CFR 1926.1052(c)(1) · Stairways in construction
Serious$1,600$1,600Jun 26, 2009Closed

Inspection 312135288 OPENED JUL 31, 2008Closed

Planned · Partial · Safety · 14 employees at the site · Closed Nov 10, 2008

27748 Hwy 50 Frontage Rd., La Junta, CO 81030 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.25(b) · Housekeeping
Other-than-serious$2,500$500Sep 29, 2008Closed
Citation 1, item 2
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Other-than-serious$875$875Sep 26, 2008Closed
Citation 1, item 3
29 CFR 1926.501(b)(10) · Fall protection in construction
Other-than-serious$2,500$1,000Sep 29, 2008Closed
Citation 1, item 4
29 CFR 1926.1052(c)(1) · Stairways in construction
Other-than-serious$700$700Sep 26, 2008Closed
Citation 1, item 5
29 CFR 1926.1053(b)(7) · Ladders in construction
Other-than-serious$700$700Sep 26, 2008Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)

(1) Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped with:

29 CFR 1926.1052(c)(1)(i)

(i) At least one handrail; and

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(7)

(7) Ladders shall not be used on slippery surfaces unless secured or provided with slip-resistant feet to prevent accidental displacement. Slip-resistant feet shall not be used as a substitute for care in placing, lashing, or holding a ladder that is used upon slippery surfaces including, but not limited to, flat metal or concrete surfaces that are constructed so they cannot be prevented from becoming slippery.

29 CFR 1926.150 · Fire protection

29 CFR 1926.25 · Housekeeping

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.601 · Motor vehicles

Other commercial and institutional building construction employers in Colorado

Alert subscribers get notified of each newly cited employer in Colorado the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.