OSHA SearchOSHA records by employer

Tereso Puente: OSHA inspections and violations

Coppell, Texas · Roofing Contractors · NAICS 238160

2inspections
4citation items
$16,959current penalties
Nov 3, 2020last inspection

Tereso Puente has 2 OSHA inspections on record in Texas, the first in 2017.

OSHA's last visit started on Nov 3, 2020 as a planned inspection, in Irving.

Across those inspections OSHA issued 4 citation items: 3 serious and 1 repeat.

OSHA proposed $19,878 in penalties. After settlements and reviews the total is $16,959, down 15%.

Most often, OSHA cited 1926.501, fall protection in construction (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Tereso Puente averages $8,480 over 2 cited inspections in that time.

Tereso Puente: OSHA citation items per year, 2017 to 2020
Citation items per year, by inspection date.

Want to know if OSHA cites Tereso Puente again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 345012967 OPENED NOV 3, 2020Closed

Planned · Partial · Safety · 4 employees at the site · Closed Sep 22, 2023

4419 Wildbriar Dr, Irving, TX 75061 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.302(e)(11) · Power-operated hand tools
Serious$4,453$4,453Jan 7, 2021Final
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$8,906$8,906Jan 7, 2021Final

Inspection 342264389 OPENED APR 20, 2017Closed

Planned · Partial · Safety · 3 employees at the site · Closed Mar 28, 2023

327 Oxford Place, Coppell, TX 75019 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$2,716$1,800Jun 14, 2017Final
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$3,803$1,800Jun 14, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.302 · Power-operated hand tools

29 CFR 1926.302(e)(11)

(11) All tools shall be used with the correct shield, guard, or attachment recommended by the manufacturer.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(2)

(2) Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and walkway shall be at least 18 inches (46 cm) wide.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.

Other roofing contractors employers in Texas

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.