OSHA SearchOSHA records by employer

Terry George Construction Inc.: OSHA inspections and violations

Tooele, Utah · New Single-Family Housing Construction (except For-Sale Builders) · NAICS 236115

1inspections
8citation items
$750current penalties
Apr 2, 2020last inspection

Terry George Construction Inc. has one OSHA inspection on record in Utah.

OSHA opened it on Apr 2, 2020 as a planned inspection, in Tooele.

From that inspection OSHA issued 8 citation items: 8 serious.

OSHA proposed $1,500 in penalties. After settlements and reviews the total is $750, down 50%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (6 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Terry George Construction Inc. averages $750 over 1 cited inspection in that time.

Terry George Construction Inc.: OSHA citation items per year, 2020 to 2020
Citation items per year, by inspection date.

Utah · latest 90 days of OSHA records

67employers cited

Get notified the morning OSHA posts each new citation in Utah: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Utah

Checking a subcontractor, a client or your own company? Watch Terry George Construction Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344716709 OPENED APR 2, 2020Closed

Planned · Partial · Safety · 3 employees at the site · Closed May 1, 2020

45 Memory Ln, Tooele, UT 84074 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$1,500$750Apr 13, 2020Final
Citation 1, item 1b
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$0$0Apr 13, 2020Final
Citation 1, item 1c
29 CFR 1926.451(c)(3) · Scaffolds, general requirements
Serious$0$0Apr 13, 2020Final
Citation 1, item 1d
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Apr 13, 2020Final
Citation 1, item 1e
29 CFR 1926.451(f)(4) · Scaffolds, general requirements
Serious$0$0Apr 13, 2020Final
Citation 1, item 1f
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Apr 13, 2020Final
Citation 1, item 1g
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$0$0Apr 13, 2020Final
Citation 1, item 1h
29 CFR 1926.454(a)(1) · Scaffold training
Serious$0$0Apr 13, 2020Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(c)(3)

(3) Supported scaffold poles, legs, posts, frames, and uprights shall be plumb and braced to prevent swaying and displacement.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

Other new single-family housing construction (except for-sale builders) employers in Utah

Alert subscribers get notified of each newly cited employer in Utah the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.