Inspection 345529606 OPENED SEP 14, 2021Closed
218 Barker Rd, El Paso, TX 79915 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Texas Electrical Contractors, LLC has 4 OSHA inspections on record in Texas, the first in 2017.
OSHA's last visit started on Sep 14, 2021 as a planned inspection, in El Paso.
Across those inspections OSHA issued 5 citation items: 2 serious and 3 other-than-serious.
OSHA proposed $16,918 in penalties. After settlements and reviews the total is $9,773, down 42%.
Most often, OSHA cited 1926.405, job-site wiring (2 items).
For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Texas Electrical Contractors, LLC averages $4,886 over 2 cited inspections in that time.
Texas Electrical Contractors, LLC also files yearly injury logs with OSHA, summarized below.
Texas · latest 90 days of OSHA records
393employers cited
7 of them in the same industry
Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Texas
Checking a subcontractor, a client or your own company? Watch Texas Electrical Contractors, LLC and get notified the morning OSHA posts a new citation for it.
Watch this company218 Barker Rd, El Paso, TX 79915 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
9473 Socorro Rd., Socorro, TX 79927 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
4642 N. Mesa St., El Paso, TX 79912 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.416(e)(2) · Electrical safety in construction |
Other-than-serious | $3,880 | $1,950 | Jan 10, 2018 | Final |
| Citation 1, item 2 29 CFR 1926.405(g)(2)(iv) · Job-site wiring |
Other-than-serious | $0 | $0 | Jan 10, 2018 | Final |
| Citation 1, item 3 29 CFR 1926.405(g)(2)(v) · Job-site wiring |
Other-than-serious | $0 | $0 | Jan 10, 2018 | Final |
145 Sunset, El Paso, TX 79932 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.453(b)(2)(v) · Aerial lifts |
Serious | $8,149 | $4,889 | Feb 21, 2017 | Final |
| Citation 1, item 2 29 CFR 1926.454(c) · Scaffold training |
Serious | $4,889 | $2,933 | Feb 21, 2017 | Final |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the El Paso site logged 1 recordable injury or illness among about 110 workers: 0.8 per 100 full-time workers, against a median of 1.8 for its industry. Those cases cost 204 days away from work.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| Texas Electrical Contractors LLC El Paso · 2025 | 110 | 1 | 1 | 0.8 | 1.8 |
Included with any plan: 2 more yearly logs from these sites, back to 2023, with each site's average rate over its latest three years. Already a subscriber? Sign in.
See plansCurrent text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.405(g)(2)(iv)
(iv) Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.
29 CFR 1926.405(g)(2)(v)
(v) Cords passing through holes. Flexible cords and cables shall be protected by bushings or fittings where passing through holes in covers, outlet boxes, or similar enclosures.
29 CFR 1926.416(e)(2)
(2) Extension cords shall not be fastened with staples, hung from nails, or suspended by wire.
Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.