OSHA SearchOSHA records by employer

Texpac Hide & Skin, Ltd.: OSHA inspections and violations

Fort Worth, Texas · Leather and Hide Tanning and Finishing · NAICS 316110

2inspections
8citation items
$18,154current penalties
Oct 7, 2020last inspection

Texpac Hide & Skin, Ltd. has 2 OSHA inspections on record in Texas, the first in 1995.

OSHA's last visit started on Oct 7, 2020 after a complaint, in Fort Worth.

Across those inspections OSHA issued 8 citation items: 7 serious and 1 other-than-serious.

OSHA proposed $25,944 in penalties. After settlements and reviews the total is $18,154, down 30%.

Most often, OSHA cited 1910.212, machine guarding (2 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,875. Texpac Hide & Skin, Ltd. averages $9,716 over 1 cited inspection in that time.

1 inspection on this page followed a fatal incident.

Texpac Hide & Skin, Ltd. also files yearly injury logs with OSHA, summarized below.

Texpac Hide & Skin, Ltd.: OSHA citation items per year, 1995 to 2020
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

401employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Texpac Hide & Skin, Ltd. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344963533 OPENED OCT 7, 2020Closed

Complaint · Complete · Health · 62 employees at the site · Closed Dec 30, 2021

601 Ne 29th Street, Fort Worth, TX 76106 · Leather and Hide Tanning and Finishing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Other-than-serious$6,747$4,048Jan 11, 2021Final
Citation 1, item 3
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Serious$5,398$3,239Jan 11, 2021Final
Citation 1, item 4
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$4,048$2,429Jan 11, 2021Final

Inspection 110041621 OPENED AUG 14, 1995Closed

Accident · Partial · Health · 60 employees at the site · Closed Sep 4, 1996

601 N.e. 29th St., Fort Worth, TX 76106 · OSHA's record · Phone and website on Google Maps

Incident on Aug 13, 1995 (fatal): Employee killed when crushed in flesher machine

At approximately 1:40 a.m. on August 13, 1995, Employee #1, of Texpac Hide & Ski n Ltd., was cleaning in the 10 1/2 ft heavy duty flesher area. Employee #1 was t he operator of the flesher on the evening shift from 3:30 p.m. to midnight. He a nd a coworker were to clean the floor in this area following the shift. Another coworker, a member of the cleanup crew which worked from 10:30 p.m. to 2:00 or 3 :00 a.m., was cleaning the flesher machine itself. Employee #1 was reaching into a gap of approximately 12 in. between a stationary drive shaft and an articulat ing drive shaft when the cleanup crew member, who was unaware of Employee #1's p osition, contacted a foot pedal, which caused the flesher to close. On closing, the articulated shaft rotated up and under the stationary shaft, catching and co mpressing Employee #1's head and killing him. The flesher was equipped with an e lectrically interlocked, 4-pedal, safety opening and closing system, which was d esigned to require near simultaneous (within 1 sec) contact of foot pedals by tw o operators at separate operating stations to initiate closing. Failure of a tim e delay relay in the safety system permitted employees performing cleanup to cir cumvent the system by jamming a wrench under one of the foot pedals. The flesher could then be closed by one employee activating the other foot pedals.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$2,500$2,500Oct 25, 1995Final
Citation 1, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Serious$2,500$1,250Oct 25, 1995Final
Citation 1, item 3
29 CFR 1910.212(a)(1) · Machine guarding
Serious$2,500$2,500Oct 25, 1995Final
Citation 1, item 4
29 CFR 1910.219(c)(2)(i) · Belts, pulleys and power-transmission parts
Serious$1,313$1,250Oct 25, 1995Final
Citation 1, item 5
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$938$938Oct 25, 1995Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2021, the Fort Worth site logged 7 recordable injuries or illnesses among about 104 workers: 7.7 per 100 full-time workers, against a median of 0.0 for its industry. Those cases cost 100 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Texpac Hide & Skin
Fort Worth · 2021
104 747.70.0

Included with any plan: 2 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(2)(i)

(i) An employer may provide respirators at the request of employees or permit employees to use their own respirators, if the employer determines that such respirator use will not in itself create a hazard. If the employer determines that any voluntary respirator use is permissible, the employer shall provide the respirator users with the information contained in appendix D to this section (“Information for Employees Using Respirators When Not Required Under the Standard”); and

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(1)

(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.303 · Electrical equipment, general requirements

Other leather and hide tanning and finishing employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.