OSHA SearchOSHA records by employer

Thayer Precision Carpentry, Inc: OSHA inspections and violations

Parowan, Utah · New Single-Family Housing Construction (except For-Sale Builders) · NAICS 236115

1inspections
3citation items
$319current penalties
May 20, 2015last inspection

OSHA inspectors have visited Thayer Precision Carpentry, Inc in Utah one time.

It opened on May 20, 2015 as a planned inspection, in Parowan.

In all, OSHA issued 3 citation items: 2 serious and 1 other-than-serious.

The penalties, $319 in total, stand where OSHA first set them.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Thayer Precision Carpentry, Inc averages $319 across 1 cited inspection.

Thayer Precision Carpentry, Inc: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Utah · latest 90 days of OSHA records

67employers cited

Get notified the morning OSHA posts each new citation in Utah: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Utah

Checking a subcontractor, a client or your own company? Watch Thayer Precision Carpentry, Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340654979 OPENED MAY 20, 2015Closed

Planned · Partial · Safety · 4 employees at the site · Closed Aug 4, 2015

260 North 300 East, Parowan, UT 84761 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.403(b)(1)(iii) · Electrical equipment on job sites
Serious$319$319Jul 13, 2015Final
Citation 1, item 1b
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Serious$0$0Jul 13, 2015Final
Citation 2, item 1
29 CFR 1926.503(b)(1) · Fall protection training in construction
Other-than-serious$0$0Jul 13, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(1)(iii)

(iii) Electrical insulation.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(g)(2)(iv)

(iv) Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.

29 CFR 1926.503 · Fall protection training in construction

29 CFR 1926.503(b)(1)

(b) Certification of training. (1) The employer shall verify compliance with paragraph (a) of this section by preparing a written certification record. The written certification record shall contain the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. If the employer relies on training conducted by another employer or completed prior to the effective date of this section, the certification record shall indicate the date the employer determined the prior training was adequate rather than the date of actual training.

Other new single-family housing construction (except for-sale builders) employers in Utah

Alert subscribers get notified of each newly cited employer in Utah the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.