OSHA SearchOSHA records by employer

The Bentcil Company: OSHA inspections and violations

Indianapolis, Indiana · All Other Plastics Product Manufacturing · NAICS 326199

2inspections
6citation items
$2,665current penalties
Sep 9, 2015last inspection

Since 2014, OSHA inspectors have visited The Bentcil Company in Indiana 2 times.

The most recent inspection opened on Sep 9, 2015 on a referral, in Indianapolis.

In all, OSHA issued 6 citation items: 5 serious and 1 other-than-serious.

The proposed penalties came to $4,100; today they stand at $2,665, 35% less.

The rule cited most here is 1910.106 (flammable liquids), 4 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. The Bentcil Company averages $1,755 across 1 cited inspection.

The Bentcil Company: OSHA citation items per year, 2014 to 2015
Citation items per year, by inspection date.

Indiana · latest 90 days of OSHA records

79employers cited

Get notified the morning OSHA posts each new citation in Indiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Indiana

Checking a subcontractor, a client or your own company? Watch The Bentcil Company and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340919448 OPENED SEP 9, 2015Closed

Referral · Partial · Health · 84 employees at the site · Closed Apr 2, 2019

1755 Midwest Boulevard, Indianapolis, IN 46214 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Serious$900$585Mar 8, 2016Final
Citation 1, item 2
29 CFR 1910.106(e)(2)(iv)(a) · Flammable liquids
Serious$900$585Mar 8, 2016Final
Citation 1, item 3
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$900$585Mar 8, 2016Final

Inspection 317459337 OPENED OCT 24, 2014Closed

Complaint · Partial · Health · 65 employees at the site · Closed May 29, 2015

1755 Midwest Boulevard, Indianapolis, IN 46214 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$700$455Apr 16, 2015Closed
Citation 1, item 2
29 CFR 1910.106(e)(9)(iii) · Flammable liquids
Serious$700$455Apr 16, 2015Closed
Citation 2, item 1
29 CFR 1910.1200(h)(3)(iv) · Hazard communication
Other-than-serious$0$0Apr 16, 2015Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(4)(i)

(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra

29 CFR 1910.106(e)(2)(iv)(a)

(iv) Handling liquids at point of final use. (a) Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be kept in covered containers when not actually in use.

29 CFR 1910.106(e)(6)(ii)

(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.303 · Electrical equipment, general requirements

Other all other plastics product manufacturing employers in Indiana

Alert subscribers get notified of each newly cited employer in Indiana the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.