Inspection 347716524 OPENED AUG 28, 2024Closed
628 South Main Street, North Syracuse, NY 13212 · Cookie and Cracker Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
North Syracuse, New York · Cookie and Cracker Manufacturing · NAICS 311821
OSHA has inspected The Decorated Cookie Co LLC 2 times in New York since 2022.
The latest one began on Aug 28, 2024 to follow up on an earlier case, in North Syracuse.
Those inspections ended with 2 citation items: 2 serious.
Penalties were first proposed at $15,625 and now stand at $7,657, 51% lower after settlements or reviews.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,875, and The Decorated Cookie Co LLC averages $7,657 (1 cited inspection).
New York · latest 90 days of OSHA records
362employers cited
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New York
Checking a subcontractor, a client or your own company? Watch The Decorated Cookie Co LLC and get notified the morning OSHA posts a new citation for it.
Watch this company628 South Main Street, North Syracuse, NY 13212 · Cookie and Cracker Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
628 South Main Street, North Syracuse, NY 13212 · Cookie and Cracker Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.147(c)(1) · Lockout/tagout |
Serious | $10,938 | $7,657 | Mar 17, 2023 | Final |
| Citation 1, item 2 29 CFR 1910.157(b)(1) · Portable fire extinguishers |
Serious | $4,687 | $0 | Mar 17, 2023 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.147(c)(1)
(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.
29 CFR 1910.157(b)(1)
(b) Exemptions. (1) Where the employer has established and implemented a written fire safety policy which requires the immediate and total evacuation of employees from the workplace upon the sounding of a fire alarm signal and which includes an emergency action plan and a fire prevention plan which meet the requirements of 29 CFR 1910.38 and 29 CFR 1910.39 respectively, and when extinguishers are not available in the workplace, the employer is exempt from all requirements of this section unless a specific standard in part 1910 requires that a portable fire extinguisher be provided.