Inspection 347486276 OPENED MAY 16, 2024Closed
83 Stickleback Drive, Willow Spring, NC 27592 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Durham, North Carolina · New Single-Family Housing Construction (except For-Sale Builders) · NAICS 236115
OSHA has inspected The Drees Homes Company 13 times in North Carolina since 1999.
The latest one began on May 16, 2024, in Willow Spring.
Those inspections ended with 3 citation items: 3 serious.
Penalties were first proposed at $2,875 and now stand at $2,020, 30% lower after settlements or reviews.
Scaffolds, general requirements comes up most often in these citations: 2 items under 1926.451.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and The Drees Homes Company averages $1,125 (1 cited inspection).
The Drees Homes Company also files yearly injury logs with OSHA, summarized below.
North Carolina · latest 90 days of OSHA records
228employers cited
3 of them in the same industry
Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in North Carolina
Checking a subcontractor, a client or your own company? Watch The Drees Homes Company and get notified the morning OSHA posts a new citation for it.
Watch this company83 Stickleback Drive, Willow Spring, NC 27592 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
128 South Clearbrook, Angier, NC 27501 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
77 South Clearbrook Court, Angier, NC 27501 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
39 Streamside Drive, Angier, NC 27501 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Adkins Ridge Rd, Rolesville, NC 27571 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements |
Serious | $1,500 | $1,125 | Jun 19, 2020 | Final |
2024 Golden Belt Parkway, Durham, NC 27703 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
4702 Cumberlan Drive, Durham, NC 27705 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
522 Redford Place Drive, Rolesville, NC 27571 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
205 Cole Velley Drive Lot 24, Cary, NC 27513 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
202-212 Irving Way, Durham, NC 27703 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
506 Cole Stream Court, Cary, NC 27513 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Lot #41 Avallon Subdivision, Raleigh, NC 27612 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 2a 29 CFR 1926.451(e)(1) · Scaffolds, general requirements |
Serious | $1,375 | $895 | Mar 9, 2004 | Closed |
| Citation 1, item 2b 29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements |
Serious | $0 | $0 | Mar 9, 2004 | Closed |
214 Castlebury Dr., Apex, NC 27502 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Raleigh site logged 0 recordable injuries or illnesses among about 60 workers: 0.0 per 100 full-time workers, against a median of 1.8 for its industry.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| 500-Drees-Raleigh Raleigh · 2025 | 60 | 0 | 0 | 0.0 | 1.8 |
| Raleigh site Raleigh · 2019 | 42 | 1 | 0 | 2.8 | 1.8 |
Included with any plan: 7 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
See plansCurrent text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.451(e)(1)
(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.
29 CFR 1926.451(g)(4)(i)
(i) Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews.
29 CFR 1926.701(b)
(b) Reinforcing steel. All protruding reinforcing steel, onto and into which employees could fall, shall be guarded to eliminate the hazard of impalement.
Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.