Inspection 348999848 OPENED JUN 15, 2026Closed
204 Calle Norzagaray, San Juan, 00901, Viejo San Juan, PR 00901 · Hotels (except Casino Hotels) and Motels · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
San Juan, Puerto Rico · Hotels (except Casino Hotels) and Motels · NAICS 721110
OSHA has inspected The Gallery Inn Inc 2 times in Puerto Rico since 2025.
The latest one began on Jun 15, 2026 after a complaint, in Viejo San Juan.
Those inspections ended with 3 citation items: 3 serious.
Penalties were first proposed at $3,600 and still stand at $3,600.
Electrical wiring methods comes up most often in these citations: 3 items under 1910.305.
How that compares: the median penalty per cited inspection for hotel and restaurant employers since 2015 is $1,350, and The Gallery Inn Inc averages $3,600 (1 cited inspection).
Puerto Rico · latest 90 days of OSHA records
109employers cited
2 of them in the same industry
Get notified the morning OSHA posts each new citation in Puerto Rico: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Puerto Rico
Checking a subcontractor, a client or your own company? Watch The Gallery Inn Inc and get notified the morning OSHA posts a new citation for it.
Watch this company204 Calle Norzagaray, San Juan, 00901, Viejo San Juan, PR 00901 · Hotels (except Casino Hotels) and Motels · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
204 Norzagaray, San Juan, PR 00901 · Hotels (except Casino Hotels) and Motels · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.305(b)(2)(i) · Electrical wiring methods |
Serious | $1,500 | $1,500 | Dec 12, 2025 | Final |
| Citation 1, item 2a 29 CFR 1910.305(g)(1)(iv) · Electrical wiring methods |
Serious | $2,100 | $2,100 | Dec 12, 2025 | Final |
| Citation 1, item 2b 29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods |
Serious | $0 | $0 | Dec 12, 2025 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.305(b)(2)(i)
(2) Covers and canopies. (i) All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.
29 CFR 1910.305(g)(1)(iv)
(iv) Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used:
29 CFR 1910.305(g)(2)(ii)
(ii) Flexible cords may be used only in continuous lengths without splice or tap. Hard-service cord and junior hard-service cord No. 14 and larger may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced.
Alert subscribers get notified of each newly cited employer in Puerto Rico the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.