OSHA SearchOSHA records by employer

The Hill Group dba Hill Mechanical Corp.: OSHA inspections and violations

Evanston, Illinois · Plumbing, Heating, and Air-Conditioning Contractors · NAICS 238220

1inspections
14citation items
$71,439current penalties
Oct 11, 2019last inspection

OSHA inspectors have visited The Hill Group dba Hill Mechanical Corp. in Illinois one time.

It opened on Oct 11, 2019 on a referral, in Evanston.

In all, OSHA issued 14 citation items: 14 serious.

The proposed penalties came to $105,835; today they stand at $71,439, 33% less.

The rule cited most here is 1910.146 (permit-required confined spaces), 14 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. The Hill Group dba Hill Mechanical Corp. averages $71,439 across 1 cited inspection.

The Hill Group dba Hill Mechanical Corp.: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Illinois · latest 90 days of OSHA records

414employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Illinois

Checking a subcontractor, a client or your own company? Watch The Hill Group dba Hill Mechanical Corp. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344386800 OPENED OCT 11, 2019Closed

Referral · Partial · Safety · 2 employees at the site · Closed Mar 9, 2022

2170 Campus Dr., Evanston, IL 60201 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Incident on Oct 10, 2019: Employee suffers burns when steam pipe bursts

At 10:00 a.m. on October 10, 2019, an employee was troubleshooting a leak in a steam trap in a steam vault when a high pressure pipe burst releasing steam at 230 psi and 480 degrees Fahrenheit. The employee was hospitalized to treat second and third degree burns.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.146(c)(9)(i) · Permit-required confined spaces
Serious$12,145$7,938Apr 1, 2020Final
Citation 1, item 2a
29 CFR 1910.146(c)(9)(ii) · Permit-required confined spaces
Serious$12,145$7,938Apr 1, 2020Final
Citation 1, item 2b
29 CFR 1910.146(d)(11) · Permit-required confined spaces
Serious$0$0Apr 1, 2020Final
Citation 1, item 3
29 CFR 1910.146(d)(2) · Permit-required confined spaces
Serious$12,145$7,938Apr 1, 2020Final
Citation 1, item 4a
29 CFR 1910.146(d)(3)(iii) · Permit-required confined spaces
Serious$12,145$7,938Apr 1, 2020Final
Citation 1, item 4b
29 CFR 1910.146(d)(3)(vi) · Permit-required confined spaces
Serious$0$0Apr 1, 2020Final
Citation 1, item 5
29 CFR 1910.146(d)(5)(i) · Permit-required confined spaces
Serious$8,675$7,938Apr 1, 2020Final
Citation 1, item 6a
29 CFR 1910.146(d)(8) · Permit-required confined spaces
Serious$12,145$7,938Apr 1, 2020Final
Citation 1, item 6b
29 CFR 1910.146(g)(1) · Permit-required confined spaces
Serious$0$0Apr 1, 2020Final
Citation 1, item 7
29 CFR 1910.146(e)(1) · Permit-required confined spaces
Serious$12,145$7,938Apr 1, 2020Final
Citation 1, item 8a
29 CFR 1910.146(k)(1)(i) · Permit-required confined spaces
Serious$12,145$7,938Apr 1, 2020Final
Citation 1, item 8b
29 CFR 1910.146(k)(1)(iv) · Permit-required confined spaces
Serious$0$0Apr 1, 2020Final
Citation 1, item 8c
29 CFR 1910.146(k)(1)(v) · Permit-required confined spaces
Serious$0$0Apr 1, 2020Final
Citation 1, item 9
29 CFR 1910.146(k)(3) · Permit-required confined spaces
Serious$12,145$7,938Apr 1, 2020Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.146(c)(9)(i)

(i) Obtain any available information regarding permit space hazards and entry operations from the host employer;

29 CFR 1910.146(c)(9)(ii)

(ii) Coordinate entry operations with the host employer, when both host employer personnel and contractor personnel will be working in or near permit spaces, as required by paragraph (d)(11) of this section; and

29 CFR 1910.146(d)(11)

(11) Develop and implement procedures to coordinate entry operations when employees of more than one employer are working simultaneously as authorized entrants in a permit space, so that employees of one employer do not endanger the employees of any other employer;

Other plumbing, heating, and air-conditioning contractors employers in Illinois

Alert subscribers get notified of each newly cited employer in Illinois the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.