OSHA SearchOSHA records by employer

The Home Makers 4 U, LLC: OSHA inspections and violations

Norfolk, Virginia · Roofing Contractors · NAICS 238160

1inspections
6citation items
$4,320current penalties
Aug 14, 2018last inspection

OSHA inspectors have visited The Home Makers 4 U, LLC in Virginia one time.

It opened on Aug 14, 2018 after a complaint, in Norfolk and is still open.

In all, OSHA issued 6 citation items: 6 serious.

The penalties, $4,320 in total, stand where OSHA first set them.

The rule cited most here is 1926.404 (ground-fault protection on job sites), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. The Home Makers 4 U, LLC averages $4,320 across 1 cited inspection.

The Home Makers 4 U, LLC: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

250employers cited

23 of them in the same industry

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch The Home Makers 4 U, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343410817 OPENED AUG 14, 2018Open

Complaint · Partial · Safety · 5 employees at the site · Open

6240 Chesapeake Boulevard, Norfolk, VA 23513 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$2,160$2,160Sep 20, 2018Final
Citation 1, item 1b
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$0$0Sep 20, 2018Final
Citation 1, item 1c
29 CFR 1926.405(a)(2)(ii)(i) · Job-site wiring
Serious$0$0Sep 20, 2018Final
Citation 1, item 1d
29 CFR 1926.416(e)(1) · Electrical safety in construction
Serious$0$0Sep 20, 2018Final
Citation 1, item 2a
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$2,160$2,160Sep 20, 2018Final
Citation 1, item 2b
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$0$0Sep 20, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.404(f)(6)

(6) Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(a)(2)(ii)(i)

(iii) Guarding. For temporary wiring over 600 volts, nominal, fencing, barriers, or other effective means shall be provided to prevent access of other than authorized and qualified personnel.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other roofing contractors employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.