OSHA SearchOSHA records by employer

The Kmak Group LLC: OSHA inspections and violations

Mount Sterling, Ohio · Other Motor Vehicle Parts Manufacturing · NAICS 336390

3inspections
7citation items
$7,260current penalties
Mar 12, 2024last inspection

OSHA has inspected The Kmak Group LLC 3 times in Ohio since 2024.

The latest one began on Mar 12, 2024 on a referral, in Mount Sterling.

Those inspections ended with 7 citation items: 5 serious and 2 other-than-serious.

Penalties were first proposed at $14,520 and now stand at $7,260, 50% lower after settlements or reviews.

Lockout/tagout comes up most often in these citations: 5 items under 1910.147.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and The Kmak Group LLC averages $3,630 (2 cited inspections).

The Kmak Group LLC also files yearly injury logs with OSHA, summarized below.

The Kmak Group LLC: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

263employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch The Kmak Group LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347338519 OPENED MAR 12, 2024Closed

Referral · Partial · Health · 41 employees at the site · Closed Jul 10, 2024

480 Alcott Dr, Mount Sterling, OH 43143 · Other Motor Vehicle Parts Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Other-than-serious$0$0May 31, 2024Final
Citation 1, item 1b
29 CFR 1910.134(c)(2)(ii) · Respiratory protection
Other-than-serious$0$0May 31, 2024Final

Inspection 347329609 OPENED MAR 7, 2024Closed

Complaint · Partial · Safety · 41 employees at the site · Closed Aug 19, 2024

480 Alcott Dr, Mount Sterling, OH 43143 · Other Motor Vehicle Parts Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$7,260$7,260May 22, 2024Final
Citation 1, item 1b
29 CFR 1910.147(c)(8) · Lockout/tagout
Serious$0$0May 22, 2024Final
Citation 1, item 1c
29 CFR 1910.147(d)(6) · Lockout/tagout
Serious$0$0May 22, 2024Final
Citation 1, item 1d
29 CFR 1910.147(f)(3)(i) · Lockout/tagout
Serious$0$0May 22, 2024Final
Citation 1, item 1e
29 CFR 1910.147(c)(7)(i)(a) · Lockout/tagout
Serious$7,260$0May 22, 2024Final

Inspection 347234866 OPENED JAN 25, 2024Closed

Complaint · Partial · Safety · 38 employees at the site · Closed Mar 7, 2024

480 Alcott Dr, Mount Sterling, OH 43143 · Other Motor Vehicle Parts Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2024, the Mount Sterling site logged 1 recordable injury or illness among about 42 workers: 2.9 per 100 full-time workers, against a median of 2.7 for its industry. Those cases cost 5 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
KMAK Group LLC
Mount Sterling · 2024
42 112.92.7

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(2)(i)

(i) An employer may provide respirators at the request of employees or permit employees to use their own respirators, if the employer determines that such respirator use will not in itself create a hazard. If the employer determines that any voluntary respirator use is permissible, the employer shall provide the respirator users with the information contained in appendix D to this section (“Information for Employees Using Respirators When Not Required Under the Standard”); and

29 CFR 1910.134(c)(2)(ii)

(ii) In addition, the employer must establish and implement those elements of a written respiratory protection program necessary to ensure that any employee using a respirator voluntarily is medically able to use that respirator, and that the respirator is cleaned, stored, and maintained so that its use does not present a health hazard to the user. Exception: Employers are not required to include in a written respiratory protection program those employees whose only use of respirators involves the voluntary use of filtering facepieces (dust masks).

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

Other other motor vehicle parts manufacturing employers in Ohio

Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.