The Parkchester North Condominium: OSHA inspections and violations
Bronx, New York · Residential Property Managers · NAICS 531311
1inspections
2citation items
$10,426current penalties
Jan 8, 2026last inspection
OSHA has inspected The Parkchester North Condominium once in New York.
The inspection began on Jan 8, 2026 after a complaint, in Bronx.
That inspection ended with 2 citation items: 2 serious.
Penalties were first proposed at $14,895 and now stand at $10,426, 30% lower after settlements or reviews.
Woodworking machinery comes up most often in these citations: 2 items under 1910.213.
How that compares: the median penalty per cited inspection for real estate and rental employers since 2015 is $1,850, and The Parkchester North Condominium averages $10,426 (1 cited inspection).
The Parkchester North Condominium also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
New York · latest 90 days of OSHA records
362employers cited
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
Checking a subcontractor, a client or your own company? Watch The Parkchester North Condominium and get notified the morning OSHA posts a new citation for it.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2024, the Bronx site logged 7 recordable injuries or illnesses among about 111 workers: 7.6 per 100 full-time workers, against a median of 1.0 for its industry. Those cases cost 487 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
The Parkchester North Condominium
Bronx · 2024
111
7
7
7.6
1.0
Included with any plan: 7 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(c) Hand-fed ripsaws. (1) Each circular hand-fed ripsaw shall be guarded by a hood which shall completely enclose that portion of the saw above the table and that portion of the saw above the material being cut. The hood and mounting shall be arranged so that the hood will automatically adjust itself to the thickness of and remain in contact with the material being cut but it shall not offer any considerable resistance to insertion of material to saw or to passage of the material being sawed. The hood shall be made of adequate strength to resist blows and strains incidental to reasonable operation, adjusting, and handling, and shall be so designed as to protect the operator from flying splinters and broken saw teeth. It shall be made of material that is soft enough so that it will be unlikely to cause tooth breakage. The hood shall be so mounted as to insure that its operation will be po
29 CFR 1910.213(h)(1)
(h) Radial saws. (1) The upper hood shall completely enclose the upper portion of the blade down to a point that will include the end of the saw arbor. The upper hood shall be constructed in such a manner and of such material that it will protect the operator from flying splinters, broken saw teeth, etc., and will deflect sawdust away from the operator. The sides of the lower exposed portion of the blade shall be guarded to the full diameter of the blade by a device that will automatically adjust itself to the thickness of the stock and remain in contact with stock being cut to give maximum protection possible for the operation being performed.
Other residential property managers employers in New York
Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.